Studer Innotec C1312 COMPACT, C3548 COMPACT, C2324 COMPACT Transfer system, Charging current

Page 16

STUDER INNOTEC

COMPACT

the OUTPUT less it’s give to the charger. Priority for the OUTPUT. When the power sharing is used the LED 200% (red) is lit to point out that’s the charge is limited.

Caution: If the power use on the OUTPUT is higher than the value of the INPUT LIMIT (26) the COMPACT limit the current, then the generator means to stop or the circuit breaker before means to break.

In option, a remote control (RPS-01, 20m cable) allows the Power Sharing far from the COMPACT.

4.6.3.1 Set the INPUT LIMIT (26)

The current available for the COMPACT depend of the supply used i.e. motor generator, network limit in a camping or shore connections… The value of the turning knobs INPUT LIMIT (26) must by adjust lower or equal of the current available from the source.

For example if you have a generator of 2kW you must adjust the turning knobs 26 to approximately 8.5A. For calculate this, we divide the nominal power (2000W) by the voltage (230V). If you have a circuit breaker (i.e. 6A) before the COMPACT, then you set this value on the turning knobs (26) (i.e. 6A).

Generator Current

power (230V)

500W 2A

900W 4A

1500W 6,5A

2000W 8,5A

3000W 13A

4.6.4Charging current:

The maximum charging current for the battery can be adjusted with the Turning Knob 22 (CHARGER). The charging current of the battery should be set to approximately 10 – 20% of the battery capacity (at C10). This means that the charging current for a battery with 300Ah should be set between 30 – 60A.

The charging current is displayed on CURRENT MONITOR (25) of the front panel or on the Remote Control .

4.6.5Battery Condition:

Built-in microprocessor with a specially developed algorithm calculates the actual state of charge of the battery and displays it on LED 15 – 18. The LED 14 is lit when the system is carrying out a charge cycle with equalization.

For safety reasons, you must get the recommended charge voltage and charge currents from your battery supplier. The voltage levels and charge characteristics can be changed through Programming. The instruction for programming of battery charger is in the section „Programming“(Chap. 5.1.2). The correct charging is indispensable for a safe function and long-life of the battery.

14

Equalization cycle

15

Battery 75

– 100%

16

Battery 50

– 75%

17

Battery 25

– 50%

18

Battery 0 – 25%

4.7 The Transfer system

When an ac voltage is at the input AC IN of the COMPACT, the LED 1 AC IN is lit. When this voltage matches the lowest adjusted value set by the Turning Knob 23 TRANSFER, and the frequency is between 44Hz and 65Hz, this voltage is switched directly to the battery charger and to the output AC OUT. The LED 7 TRANSFER is lit. The inverter is switched off and the battery charger switched on. This process is automatic, unless the charger mode or the transfer mode is disabled (see Chap.5.5)

The maximum current of the Transfer switch is 15A. That means through this system, consuming devices up to a maximum of al 3500 Watt can be operated. When the Battery Charger is working, part of this power is used for the charging according with the power sharing system.

The Transfer system is protected against overload with an automatic safety fuse on the AC Input side of the COMPACT. If the system has been overloaded the button/pin of the fuse will pop-out. To put the automatic safety system back in to operating you must push this pin back.

User manual

COMPACT V2.0 E

16

Image 16
Contents User and installer Manual Compact V2.0 EIndex table Reset Value Battery Voltages and Absorption Time General Information Special Precautions Introduction Principe schematicDescription of main functions Battery connections Remote controlSolar charge regulator optional Parallel ConnectionAssembly Place of assemblyFixing ConnectionProtection cover for the terminals connections Connecting Plan / Front sideSolar + Cabling/wiring Connection to Remote control Connection to Temperature Sensor TempConnect the Solarmodules Solar +/- Only for solar option Connection to Auxiliary ContactOperating Display and operating control elementsPush buttons Light Emitting DiodesTurning Knobs Battery Condition InverterCharge detection system „Standby OverloadBattery charger Input current repartition Power sharingCycle of charge Equalization chargingTransfer system Charging currentFast UPS- Mode for the Transfer Switch Delayed mode of the Transfer SystemSolar charge regulator option Multifunctional ContactRemote Control Maximum Contact load -230Vac /16Amp-30Vdc/1ATemperature sensor Standard settingReset value Battery voltages and absorption timeProgram the auxiliary contact Set the voltage and timing thresholdThese four red LED show the function Set LED11Example Manual operating of Auxiliary ContactMaintenance Diagram of the different modeTechnical Data TypeSolar Charge Regulator-Floating Various data