Graco Essential Parts and Guide for ProMix 2KE Equipment

Page 18

Parts

Part No. 262398, for ProMix 2KE Proportioner, Sequential Dosing

25

47

*31

24

37

28

30

29

39*

1

21

49 48

46

31*

39*

38

5*

45

36

40*

35

 

31*

 

3

23

ti16301a

Ref.

Part

Description

Qty.

1

-----

BODY, integrator manifold

1

3

15T592

PLUG, integrator manifold

1

5*

-----

O-RING

2

21

118823

TUBE, outlet

1

23

15B588

SCREW, cap, socket hd

8

24

15D430

TUBE, static mixer

1

25

118822

ELEMENT, static mixer

2

28

118830

CLAMP, body, integrator tube

2

29

118831

COVER, clamp, integrator tube

1

30

101885

SCREW, cap, socket hd

2

31*

-----

O-RING

3

35

15T943

BASE, integrator

1

36

-----

MANIFOLD, end

2

37

15T748

SEAL, screw

1

38

15T749

SEAL, screw

1

39**

-----

O-RING

2

40*

-----

O-RING

1

45

16D658

VALVE, check

2

46

15V021

MIXER, integrator, 50cc, includes

1

 

 

parts 47-49

 

47

-----

HOUSING, integrator, 50cc

1

48

-----

CAP, mix, integrator

1

49

-----

CAP, integrator

1

*Parts included in Manifold Rebuild Kit 15U931 (pur- chase separately).

Integrator Kits

Part No.

Size

Description

 

 

 

15V021

50 cc

Includes housing, mixer, o-rings,

(standard)

 

and caps

 

 

 

24B618

100cc

Includes housing, mixer, o-rings,

(optional)

 

and cap

 

 

 

15U955

0 cc

For dynamic dosing; includes hous-

(optional)

 

ing, 6 injector restrictors, and

 

 

o-rings

 

 

 

18

312781E

Image 18
Contents Important Safety Instructions Fluid Mix ManifoldContents Related ManualsModels Air Connections InstallationFlush Before Using Equipment Fluid ConnectionsKey ProMix 2KS Fluid Station Key ProMix 3KS Fluid StationKey DVA2DVA3 behind Setup the Fluid Manifold for Dynamic Dosing Restrictor Sizes Size Code Orifice SizePurging Adjust gun atomizing air pressure as neededOperation Operation GuidelinesPreventive Maintenance Schedule MaintenanceMix Manifold Valve Settings WeeklyCommon Causes TroubleshootingIsolate a Mixing Problem Unbalanced PressureRemove the Restrictor ProMix 2KE, Dynamic Dosing only RepairRemove the Integrator Mixer Remove from the bottomRepair the Valves and Seats ProMix 2KS and ProMix 3KS only Dispense Valve CapRebuild the Mix Manifold Replace the Outlet Tube and Static Mixer TubeRepair 312781E Parts Part No , for ProMix 2KS ProportionerIntegrator Kits include parts Part No. Description QtySize Description Part No , for ProMix 3KS Proportioner Part No , for ProMix 3KS Proportioner Part No , for ProMix 2KE Proportioner, Sequential Dosing Integrator KitsPart Description Qty Part No , for ProMix 2KE Proportioner, Dynamic Dosing Restrictor KitParts Technical Data 289695, 256875, and 262398 4000 psi 28 MPa, 280 barGraco Standard Warranty Graco Information