Maintenance
Mix Manifold Valve Settings
To open dispense or purge valves, turn hex nut (E) counterclockwise. To close, turn clockwise. FIG. 4.
E
TI11581a
FIG. 4. Dispense Valve Adjustment
Table 2: Mix Manifold Valve Settings
Valve | Setting | Function | |
|
|
| |
Dose | Hex nut | Limits maximum fluid flow rate | |
| (E) | into integrator and minimizes | |
Purge | |||
turns out | valve response time. | ||
| |||
| from fully |
| |
| closed |
| |
|
|
| |
Shut- | Fully open | Closes component ports to | |
off | during | integrator during ratio check | |
| Run/Mix | or meter calibration. Open | |
| operation | ports during Run/Mix opera- | |
|
| tion. | |
|
|
| |
Sam- | Fully | Open to dispense compo- | |
pling | closed | nents while calibrating | |
| during | meters. Do not open sampling | |
| Run/Mix | valves unless fluid shutoff | |
| operation | valves are closed. | |
|
|
|
Maintenance
To reduce the risk of injury, including fluid injection, fol- low the Pressure Relief Procedure in your proportion- ing equipment manual before cleaning, checking, or repairing equipment.
Weekly
•Clean and inspect the integrator mixer assembly. Follow Remove the Integrator Mixer, page 10. Ensure that the mixer (46) holes are not clogged. The cleaning frequency required depends on the fluid being mixed.
•Clean and inspect fluid and air filters.
Daily
•Purge the mixing system at the end of production.
•Check and refill fluid supplies for all components and solvent.
•Inspect the manifold and fluid line components for leaks.
•Make sure meter cables and air pilot lines are securely connected.
•Check that there is no fluid in the air purge line.
Preventive Maintenance
Schedule
At least once a year, take apart the mix manifold and dose/purge valves and sampling valves. Clean and inspect them. Replace
8 | 312781E |