Hitachi EC 79 instruction manual Maintenance, Service and Repairs

Page 9

WARNING: Check the manufacturer’s maximum pressure rating for nailers, staplers and

accessories. Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the nailers, staplers and accessories.

Knob of the pressure switch

Knob of the pressure reducer

Pressure gauge (A)

Pressure gauge

indicates the pressure

(B) indicates the

in the air tank

working pressure

Fig.3

 

3.Shutdown

(1)Push the knob of the pressure switch to “OFF” (Refer to Fig. 1 and Fig. 2).

(2)Unplug the plug from power source.

(3)Open the drain cock located at the lower part of the tank (Fig. 4).

WARNING: Risk of bursting. When the tank gets cor- roded, there is a risk of breakdown. Water

will condense in the air tank. If not drai- ned, water will corrode and weaken the air tank causing a risk of air tank rupture. Drain tank daily or after 4 hours of use. The drain contains moisture in the air, abra- sion particles, rust, etc.. To drain tank open valve slowly and tilt compressor to empty accumulated water. Keep face and eyes away from drain cock.

Drain cock

Tank

Fig.4

English

MAINTENANCE

WARNING: Disconnect the compressor from the power source and remove the compressed

air from the air tank before performing the maintenance operations. Allow the compressor to cool before performing the maintenance operations.

1.Cleaning the intake filter

Remove the intake filter (Refer to Fig. 1) every 50 hours or once a week and clean the inside of the intake filter and the filter element with compressed air (Fig. 5). Use a phillips screwdriver to disassemble intake filter.

WARNING: Never clean filter element with a flammable liquid or solvent.

CAUTION: Do not operate without the intake filter.

Filter element

Intake filter

Fig.5

NOTE: Replace the filter element when it becomes dirty.

2.Draining tank

Drain tank daily or after 4 hours of use. Open drain cock and tilt compressor to empty accumulated water (Refer to Fig. 4).

SERVICE AND REPAIRS

All quality compressors will eventually require servicing or replacement of parts because of wear from normal use.

To assure that only authorized replacement parts will be used, all service and repairs must be performed by a HITACHI AUTHORIZED SERVICE CENTER, only.

NOTE: Specifications are subject to change without any obligation on the part of the HITACHI.

- 9 -

Image 9
Contents Model Modèle Modelo AvertissementAdvertencia English Important Information Meanings of Signal WordsImportant Safety Instructions for USE of the Compressor SafetyReplacement Parts Grounding Instructions Extension CordMinimum Gage for Cord Sets Operation and Maintenance SpecificationsName of Parts Prior to Operation ApplicationsTransport OperationService and Repairs MaintenanceInformations Importantes Signification DES Signalisations EcritesSécurité Pièces Detachees Instructions DE Mise À LA Terre Cordon DE RallongeCalibre Minimal DES Cordons Utilisation ET Entretien NOM DES ComposantsRemarque Application Avant L’UTILISATIONFonctionnement Entretien Service APRÈS-VENTE ET RéparationsInformaciones Importantes Significado DE LAS Palabras DE SeñalizaciónNota Seguridad Piezas DE Repuesto Instrucciones Para LA Puesta a Tierra Cable ProlongadorCalibre Mínimo Para LOS Cables USO Y Mantenimiento Nombre DE LOS ComponentesEspecificaciones Técnicas Antes DE LA Operación AplicacionesTransporte OperaciónServicio Y Reparaciones MantenimientoPage Code Part Name Reference Page Page Rev /2006 Cod 838 510