Panasonic FP2SH manual Serial Communication, Connect to Various Serial Devices

Page 11

Serial Communication

Connect to Various Serial Devices

Serial communication control

The CPU units have an RS232C port as standard equipment. The communication unit enables connections with RS232C/RS485/ RS422-compatible devices

CPU units

All CPU units have an RS232C port as standard equipment. They can be directly connected to a host computer or a display panel, and can also be con- nected to a modem to collect data from and change programs in devices in a remote location.

Direct connection to a control panel or a computer

FP2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display panel

 

 

 

 

 

 

 

 

 

 

 

Host computer

 

 

 

RS232C port

(commercially available PC)

Remote monitoring via a modem

Modem

Public line

Modem

 

Commercially

Special cable available

 

available cable

from Panasonic

FP2

"PCWAY" for easy data collection

The operation data managing software "PCWAY" allows FP2/FP2SH operation data to be imported into Excel* without program- ming.

* Excel is a registered trademark of the Microsoft Corporation.

Multi-communication unit (MCU)

The communication blocks are detachable

Up to two blocks to be attached can be selected among RS485, RS232C, and RS422 blocks.

FP2-MCU

Industry‘s

The 230kbps communication speed

fastest

(simultaneous two-channel communi-

 

level

cation) facilitates fast large-volume

data communications

 

Three communication blocks available.

RS232C RS422 RS485

FP2-CB232

FP2-CB422

FP2-CB485

The combination

is selectable

Multi-communication unit

 

FP2-MCU.

 

* This unit cannot operate

COM2 (the lower channel) is

without a communication

sealed before shipping to

block attached. Purchase

protect it from damage,

the above communication

e. g. if only COM1 is used.

block(s) together with this

 

unit.

08/2007

11

Image 11
Contents FP2/FP2SH Series  FP2  FP2SH CPU UnitsTop Performance, Full Range of Functions  CPU units Conventional backplane Memory and I/O ControlFlexible Expandability  Memory and I/O control Rtex positioning units System configurationPositioning Optimal Combination with Servo Drives High-speed counter units and pulse I/O units  ConfigurationHigh-Speed, High-Precision Positioning  Positioning units Analog input units Analog ControlAccurate Process Control  Analog control PLC link NetworkingConnect all PLCs with Each Other  Open networkContinuous Communication in Industrial Applications Flexible Network Slave Unit Highlights Program/Operate the PLC using an Ethernet NetworkFP Web-Server  Remote I/O systems MEWNET-F modeRemote I/O Systems Flexible Layout of I/O Devices Multi-communication unit MCU Serial CommunicationConnect to Various Serial Devices  Serial communication control Special functions  Other built-in functions  Features Performance specifications Basic CPUsLarge programming capacity of up to 120k steps Built-in comment and calendar timer functionsHigh-Performance CPUs Scanning time of 1ms for 20k stepsUnits that occupy two modules each Product Line and Accessories FP2/FP2SH system configurations and unit lineup Unit combinationsAFP8670 FP Memory LoaderData clear Data hold typeFree demonstration disc XxxxxControlXxxxxxxxFPWIN ProMost important highlights at a glance FPWINPro full version supports all FP Series PLCs FP OPC Server  Features of the FP OPC ServerOther software tools FP OPC Server and FP Data AnalyzerROM/EP-ROM XxxxxSpecificationsXxxxxxxx Power supply units XxxxxFP2/FP2SHXxxxxxxxOFF →ON Specifications Input units  Output unitsAnalog output unit FP2-DA4  Analog I/O unitsAnalog input Analog output Multi-communication units Performance SpecificationTransmission specifications for communication interface  ET-LAN units S-LINK units  Multi-wire link units FNS Flexible Network Slave specifications  Positioning units Rtex Network typePWM  Positioning units multifunction type pulse output typeFP2-PP21 FP2-PP41 FP2-PP22 FP2-PP42 FP2 Pulse I/O unit Optional memories for FP2SH XxxxxProductXxxxxxxxTypes CPU units Built-in RAM  Optional memories for FP2 Intelligent units for remote I/O control  Maintenance partsProduct Types  I/O unitsFPWINPROFEN5  Serial communication and link-related intelligent units Fpwin Pro PLC programming software according to IEC  Other software toolsL1 mm L2 mm DimensionsDIN rail mounting groove Mm wide DIN EN50022 L1 mm 140 209 265 349 405 L2 mm 130 199 255 339 395Euen 08/07 Please contact our Global Sales CompaniesFax 010