FP2/FP2SH
Specifications
ET-LAN  units
 Performance Specification
Item  | 
  | Specifications | 
  | 
  | -   | 
Communications function  | -   | |
  | 
  | - Transparent communication  | 
Number of communication connections  | 8 connections max.  | |
Transparent  | Transmit  | Factory setting: 1k words/connection x 3  | 
communications buffer  | Receive  | Factory setting: 1k words/connection x 3  | 
 Transmission specifications for communication interface
Item  | 
 | 1)  | 
 | 1)  | 100BASE5 | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | 
Transmission speed  | 100Mbit/s  | 
  | 10Mbit/s  | 
  | 10Mbit/s  | 
Transmission method  | Base band  | 
  | Base band  | 
  | Base band  | 
Max. segment length | 100m note 2)  | 
  | 100m note 2)  | 
  | 500m  | 
Max. distance between nodes  | 205m (2 segments)  | 500m (5 segments)  | 2500m (5 segments)  | ||
Communication cable or connection  | Category 5 UTP cable  | Category 3, 4 and 5 UTP cable  | Transceiver cable  | ||
Max. transceiver cable  | 
  | 
  | 50m note 3)  | ||
length  | 
  | 
  | 
  | 
  | 
  | 
Max. number of nodes  | 
  | 
  | 100 nodes/segment  | ||
Node spacing | 
  | 
  | Integer multiples of 2.5m | ||
Notes: 1) Switching between 
2)The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some cases, depending on the usage environment. Also, if the hub is positioned close to a control board, we recommend using it at a distance of 10m or less.
3)The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is positioned close to a control board, we recommend using it at a distance of 5m or less.
Multi-communication  units
  | 
 | Computer link | 1)  | 
  | 
  | |||
Item  | (Panasonic open protocol "MEWTOCOL" should be used.)  | 
  | PLC link function  | |||||
  | 
  | 
  | ||||||
  | 1:1 communications  | 1:N communications  | 1:1 communications  | 1:N communications | 
  | 
  | 
  | |
Communication  | 
  | |||||||
block used  | 
  | |||||||
  | 
  | 
  | ||||||
Interface  | RS232C RS422  | RS485  | RS232C RS422  | RS485  | 
  | RS232C  | RS485  | |
Communication  | Full duplex  | Full duplex  | 
  | Token passing  | ||||
method  | 
  | (Floating master)  | ||||||
  | 
  | 
  | 
  | 
  | ||||
Synchronization  | 
  | 
  | 
  | 
  | 
  | 
  | ||
Transmission line  | 
  | |||||||
or VCTF  | or VCTF  | 
  | or VCTF  | |||||
  | 
  | |||||||
Transmission distance  | 15m Length: 1200m max.  | Length: 1200m max.  | 15m Length: 1200m max.  | Length: 1200m max.  | 
  | 1200m (RS485) 15m (RS232C)  | ||
Transmission speed  | 300 to 230,400bps  | 300 to 230,400bps  | 300 to 230,400bps  | 300 to 230,400bps  | 
  | 115,200bps  | ||
(To be set in the system register)  | (19,200 bps when our   | (19,200 bps when our   | ||||||
  | 
  | 
  | 
  | |||||
Transmission code | ASCII, JIS7, JIS8, and binary  | ASCII, JIS7, JIS8 | 
  | 
  | −  | |||
  | 
  | Data length: 7 bits/8 bits  | 
  | 
  | 
  | −  | ||
Transmission format  | 
  | Parity: 0/Invalid/Valid (Odd/Even)  | 
  | 
  | 
  | −  | ||
  | Stop bit: 1 bit/2 bits  | 
  | 
  | 
  | −  | |||
(To be set in the system register)  | 
  | 
  | 
  | 
  | 
  | |||
Start code: With STX / Without STX  | −  | 
  | 
  | 
  | −  | |||
  | 
  | 
  | 
  | |||||
  | 
  | 
  | 
  | 
  | ||||
  | End code: CR/CR+LF/Time setting/ETX  | −  | 
  | 
  | 
  | −  | ||
Number of stations  | −  | 99 stations max.  | −  | 99 stations max.  | 
  | 16 stations max.  | ||
(32 stations max. when our   | (32 stations max. when our   | |||||||
PLC link capacity | −  | −  | −  | −  | 
  | Link relay: 1024 points  | ||
  | Link register: 128 words  | |||||||
  | 
  | 
  | 
  | 
  | 
  | |||
COM1 (upper channel)  | A  | A  | A  | A  | 
  | 
  | A  | |
COM2 (lower channel)  | A  | A  | A  | A  | 
  | 
  | N/A  | |
Number of attachable units  | 
  | 23 units max. (including 8 units for the computer link and 2 channels for the PLC link)  | 
  | 
  | 
  | |||
Supported versions | CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later  | 
  | ||||||
Note 1: The protocol can be downloaded from:   | 
  | 
  | 
  | A: Available  | ||||
  | 
  | 
  | 
  | 
  | 
  | N/A: Not available  | ||
08/2007  | 21  |