1 Introduction
Equipment specifications
18 Installing and Configuring the Avaya S8700 or S8710 Media Server
June 2004

Before you start the installation

The pre-installation team should have done the following tasks. If they were not all done, do not continue
with the installation.
Verify that the open, customer-supplied, EIA-310D (or equi valent) standard 19-inch (48-
centimeter) equipment racks are properly installed and solidly secured. Make sure that the screws
that come with the racks are there. The S8700 Media Server requires a 2-post rack. The S8710
Media Server requires a 4-post rack. If using a rack cabinet, make sure it has adequate ventilation.
Verify that the rail kit to support the S8710 Media Server are available for installation.
Verify that the rail kits, required to support the very heavy UPSs, are installed on the rack or
available for installation. For information on installing the rails, refer to the documentation that
comes with the rail kits.
Verify that the equipment rack(s) is(are) grounded per local code. See Job Ai d: Appr o ved Gr ounds
(555-245-772).
Verify that the customer provides AC power to the rack from a nonswitched outlet.
Verify that cabling for the TN2312BP Internet Protocol Server Interface (IPSI) circuit packs is
labeled and run from the control hardware rack to the port networks or that appropriate
connectivity is provided.
Verify that you have all the equipment on site. See Table 3, List of r equi red hard w are, on page 2 0
for the list of required hardware.
Equipment specifications
The media server control network components consist of two media servers, one or two Ethernet
switch(es), and two UPSs. See Table 1, Control network components specifications, on page 18.
The internal room temperature must not exceed 104° F (40�� C).
Table 1: Control network components specifications
Component
Dimensions
Weight (lb/kg)English (in.) Metric (cm) Us (h eight in rack)
Media Server
S8700
S8710 3.5h x 17d x 17w
3.4h x 26d x 17.5w 9h x 43d x 43w
8.6h x 66d x 45w 2
225/11
60/27
Ethernet Switch:
P133G2/P134G2
P333T/334T 3.5h x 14d x 19w
3.5h x 18d x 19w 9h x 35d x 48w
9h x 45d x 48w 2
211,13/5,6
16.5/7.5
UPS:
700 VA
1500 VA 3.5h x 19d x 17w
3.5h x 24d x 17w 9h x 48d x 43w
9h x 30d x 43w 2
234/15
50/23