3 Translating the IPSIs
Administering the IPSIs
48 Installing and Configuring the Avaya S8700 or S8710 Media Server
June 2004
Setting alarm activation level
1Type change system-parameters maintenance and press Enter.
2In the CPE Alarm Activation Level field, select none (default), warning, minor, or major,
depending on the level the customer wants and press Enter to effect the changes.
3Repeat for each IPSI.
Installing the translation file
1Type save translations and press Enter to save the translations to the hard drive.
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Update LSPs When Saving Translations: y
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no