Porter-Cable 36-679, 36-649, 36-678, 36-675 Extension Cords, Volt Single Phase Operation

Page 7

3.240 VOLT SINGLE PHASE OPERATION:

The motor supplied with your saw is a dual voltage, 120/240 volt motor. If it is desired to operate your saw at 240 volts, single phase, it is necessary to reconnect the motor leads in the motor junction box by following the in-structions given on the motor nameplate.

MAKE SURE MOTOR IS DISCONNECTED FROM POWER SOURCE BEFORE RECONNECTING MOTOR LEADS.

It is also necessary to replace the 120 volt plug, supplied with the motor, with a UL/CSA Listed plug suitable for 240 volts and the rated current of the saw as illustrated in Fig. C. Contact your local Authorized Delta Service Center or qualified electrician for proper procedures to install the plug. The saw must comply with all local and national electrical codes after the 240 volt plug is installed.

The saw with a 240 volt plug should only be connected to an outlet having the same configuration as the plug illustrated in Fig. C. No adapter is available or should be used with the 240 Volt plug.

IN ALL CASES, MAKE CERTAIN THE R E C E P TA C L E I N Q U E S T I O N I S P R O P E R LY GROUNDED. IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

EXTENSION CORDS

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. C

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

 

 

 

 

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

 

 

 

 

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

 

 

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

 

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

 

 

 

 

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

 

 

 

 

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

 

 

 

 

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. D-1

Fig. D-2

7

Image 7
Contents Shown Contractor’s SawImportant Safety Instructions Table of ContentsCalifornia Proposition Safety Guidelines DefinitionsImportant Safety Instructions General Safety RulesStay ALERT, Watch What YOU are DOING, Properly Support Long or Wide workpieces Additional Safety Rules for Table SawsMotor Specifications Power ConnectionsGrounding Instructions Extension Cords Volt Single Phase OperationFunctional Description Carton ContentsStand Parts Extension WingsSheet Metal Cast Iron Cast Iron Extension Extension Wings Hardware AssemblyUnpacking and Cleaning Assembly Tools RequiredStand to SAW Stand LegsBlade Tilting Raising Handwheel Installing Switch Motor Cord PIN X , Through the Inside Hole of Bracket B Disconnect Machine from Power SourceMotor to Motor Mounting Plate Motor and Motor Mounting Plate to SAWMotor PULLEY, Pulley GUARD, and Drive Belt Illustrates the motor cord connected to the switch assembly Connecting Motor Cord to Switch AssemblyBlade Guard and Splitter Assembly and Alignment Page Model 36-679 only ON/OFF SwitchModel 36-649 only Model 36-678 onlyOverload Protection Locking Switch in the OFF PositionOperation Starting and Stopping SAWTilting the Blade Raising and Lowering BladeAdjusting Table Insert Miter Gage Operation and AdjustmentTable Insert a should Always be Level with the Table Open end wrench B Changing the SAW BladeCROSS-CUTTING Never USE the Fence AS a CUT-OFF Gage When CROSS-CUTTINGConstructing a Push Stick RippingUsing Moulding Cutterhead Accessory Moulding CutterheadUsing Accessory Dado Head Power Tool Institute Using Auxiliary Wood Facing on RIP FenceConstructing a Featherboard Constructing a Push Stick TroubleshootingService MaintenanceWarranty Model BC30 30 Biesemeyer Commercial Fence Model DescriptionModel 36-648 30 Fence and Rail System Model U30 30 UnifenceCanadian PORTER-CABLE Delta Service Centers