Porter-Cable 28-475X, 28-248 instruction manual Power Connections

Page 5

POWER CONNECTIONS

A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3- prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the switch is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the machine. All line connections should make good contact. Running on low voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

MOTOR SPECIFICATIONS

Your machine is wired for 120 volt, 60 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the “OFF” position.

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.

1. All grounded, cord-connected machines:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding conductor can result in risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment- grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that accept the machine’s plug, as shown in Fig. A.

Repair or replace damaged or worn cord immediately.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

2.Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than 150 volts:

If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like the adapter illustrated in Fig. B, may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. A

Fig. B

 

5

Image 5
Contents Wood Cutting Band Saw Important Safety Instructions Safety Guidelines DefinitionsStay ALERT, Watch What YOU are Doing Additional Safety Rules For Band Saws Power Connections Functional Description Unpacking and Cleaning Band SAW Parts Motor Bracket To Stand AssemblyMotor to Motor Bracket Do not Completely Tighten the Bolt and NUT AT this TimeDust Chute TOP Plate to StandDust Port Stand Door to StandOnly be Attached with the TWO Bottom Holes in the Stand Hinge Catch a is Pointed UP AS Shown in FIGCompletely Tighten the Screws AT this Time Hinge Opening is Pointing DownMotor Pulley SAW to StandBelt to SAW and Motor Pulley Is on the Side of the Stand with the Belt Opening BSure the Slot C , in the Table is Facing Away from the ARM D Table to SAWLength Blades Blade to SAWTable Insert On / OFF Switch To Stand Locking Switch in the OFF Position Operating Controls and AdjustmentsStarting Stopping SAW Make Sure That the Motor PlugTilting the Table Adjusting Table StopsDisconnect Machine from Power Source To set the adjustable stops Adjusting Blade TensionNever Track the Blade While Tool is Running Vertical Adjustment of the Upper Blade Guide AssemblyTracking the Blade Adjusting the Upper Blade Guides and Blade Support Bearing Cutting Curves Adjusting Lower Blade Guides and Blade Support BearingOperations Probable Cause Remedy Troubleshooting GuideTrouble Blade will not Track Band SAW Blades Page PARTS, Service or Warranty Assistance AccessoriesCanadian PORTER-CABLE Delta Service Centers

28-475X, 28-248 specifications

The Porter-Cable 28-248 and 28-475X are two impressive models from Porter-Cable, a brand known for its high-quality power tools that cater to the needs of both professionals and DIY enthusiasts. These models are designed to deliver reliable performance, durability, and innovative features suitable for a wide range of applications.

The Porter-Cable 28-248 is a 28-gauge pneumatic brad nailer. This tool is compact and lightweight, making it easy to maneuver in tight spaces. One of its standout features is the tool-free depth of drive adjustment, allowing users to modify the depth of the nails without additional tools. This is particularly useful when working with different materials or when precision is paramount.

The 28-248 is equipped with a rear exhaust that directs air away from the user, keeping the workspace clean and enhancing comfort during operation. The integrated power adjustment dial lets users adjust the power depending on the material being used, providing versatility across various projects. Additionally, the 28-248 features a reload indicator that signals when it's time to refill the magazine, preventing interruptions during work.

On the other hand, the Porter-Cable 28-475X is a more robust option designed for industrial applications. It is a 27-gauge nail gun that offers a higher capacity magazine for less downtime. The 28-475X features a stainless steel magazine that ensures durability and smooth operation while reducing the risk of jams.

This model also includes a selective actuation switch, allowing users to choose between sequential and contact firing modes based on their needs. The built-in dry fire lockout mechanism is another valuable feature that prevents the tool from firing without nails, which prolongs its lifespan and ensures safety.

The ergonomic design of both models emphasizes user comfort, with features like rubber grips that minimize fatigue during prolonged use. Both tools are compatible with a variety of nail sizes and types, making them suitable for a range of tasks from cabinetry to flooring installations.

In summary, the Porter-Cable 28-248 and 28-475X stand out for their innovative features, ergonomic designs, and flexibility in application. Whether you're a contractor or a DIY hobbyist, both models offer the durability and performance needed to tackle any job efficiently.