Powermatic 2415, 2013 operating instructions Adjustments, Table Tilt, Table Stop

Page 15

Adjustments

Table Tilt

1.Loosen the lever (Figure 10).

2.Rotate the handwheel (Figure 10) clockwise to tilt table up to 45 degrees to the right, or counterclockwise to tilt the table up to 10 degrees to the left (as viewed from the operator’s position).

NOTE: If you tilt the table to the left, you must first remove the stop screw from the machine, shown in Figure 12.

3.Tighten the lever (Figure 10).

NOTE: The lever, shown in Figure 10, can be pivoted so that it doesn’t contact the band saw surface. Simply lift straight out on the lever and rotate it on the pin, then release it making sure it seats itself on the pin.

90° Table Stop

The 90° stop, shown in Figure 12, ensures the table will always be perpendicular to the blade after the table is returned to horizontal position.

Check and adjust this 90° stop as follows:

1.Disconnect machine from power source.

2.Loosen lever (Figure 10) and tilt table left until the stop screw rests against the metal platform of the Band Saw, as shown in Figure 12.

3.Place a square on the table and against the blade to check that the table is 90° to the blade. See Figure 11.

4.If table and blade are not square, loosen lock nut (Figure 12) with a 14mm wrench, and turn the head of the stop screw with a 17mm wrench. Turn the screw as needed until there is no longer light showing between the square and the blade.

5.Tighten lock nut (Figure 12) to secure the table stop in position.

6.Tighten the lever (Figure 10).

7.Check that the scale pointer (Figure 10) is at zero. If necessary, loosen the screw on the pointer and shift the pointer to zero. Tighten the screw.

Figure 10

Figure 11

Figure 12

15

Image 15
Contents Vantage Drive Elgin, Illinois Revision C 8/06Copyright WMH Tool Group More Information Warranty and ServiceTable of Contents Electrical Connections Page Page Introduction Specifications Model 2415 shown Features and TerminologyUnpacking Contents of the Shipping ContainerInstalling Fence and Rails AssemblyPage Dust Collection Grounding InstructionsVolt, Single Phase Operation Volt, Three Phase OperationExtension cords Three-Phase Test Run Converting from 230 Volt to 460 Volt Three Phase OnlyAdjustments Table TiltTable Stop Blade Tension Installing/Changing BladesBlade Tracking Upper Blade Guides and Upper Support Bearing Upper Blade Guide AssemblyLower Blade Guides and Lower Support Bearing Belt Tension Miter GaugeBlade Speed Adjustment Operating ControlsBelt Alignment Ripping General ProcedureOperation Brake PedalCrosscutting ResawingBlade Lead Blade Selection Width PitchShape Set MaterialBlade Breakage Maintenance Tire ReplacementBand Wheel Replacement For Radius Cutting Blade Selection GuideTroubleshooting Operational Problems Trouble Verify machine is connected to power Troubleshooting Mechanical and Electrical ProblemsTrouble Probable Cause Remedy Replacement PartsParts List Saw Body Assembly 2013 Band Saw Parts List Saw Body Assembly 2415 Band Saw Saw Body Assembly 2013 Parts List Table Assembly 2013 Band Saw TS-0270061 2013-253TS-0051061 TS-0270051Parts List Table Assembly 2415 Band Saw Index No. Part No Description Size Qty Table Assembly 2013 Parts List Upper Wheel Base Assembly 2013 Band Saw Parts List Upper Wheel Base Assembly 2415 Band Saw Upper Wheel Base Assembly 2013 Parts List Lower Wheel Base Assembly 2013 Band Saw TS-081C032 Parts List Lower Wheel Base Assembly 2415 Band Saw 2415-4262415-426RC Index No. Part No Description Size Qty Lower Wheel Base Assembly 2013 Parts List Guide Bracket Assembly 2013 Band Saw 2013-567 Parts List Guide Bracket Assembly 2415 Band Saw Index No. Part No Description Size Qty Guide Bracket Assembly 2013 Page Page Electrical Connections 230 Volt, 3 Phase Models 2013 Electrical Connections 460 Volt, 3 Phase Models 2013 Page Page WMH Tool Group