TABLE 2 – AHRI COOLING RATING TABLE 1-STAGE COOLING

 

 

NOM.

NET

 

 

 

 

 

COOLING

COOLING

TOTAL

 

 

 

UNIT

CAPACITY

SEER

EER

IEER

STAGES

CAPACITY

POWER (kW)

 

(TONS)

 

 

 

 

 

(MBH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04A

1

3

36.0

2.9

15.00

12.50

N/A

05A

1

4

48.5

3.7

15.60

13.00

N/A

06A

1

5

57.5

4.6

15.20

12.45

N/A

07A

1

6

73.0

6.0

N/A

12.00

13.00

 

 

 

 

 

 

 

 

TABLE 3 – AHRI COOLING RATING TABLE 2-STAGE COOLING

 

 

NOM.

NET

 

 

 

 

 

COOLING

COOLING

TOTAL

 

 

 

UNIT

CAPACITY

SEER

EER

IEER

STAGES

CAPACITY

POWER (kW)

 

(TONS)

 

 

 

 

 

(MBH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08D

2

7.5

89.0

7.4

N/A

12.00

13.00

09D

2

8.5

97.0

8.1

N/A

12.00

13.00

 

 

 

 

 

 

 

 

581J

LEGEND

 

AHRI

--- Air Conditioning, Heating and Refrigeration

 

Institute Test Standard

ASHRAE

--- American Society of Heating, Refrigerating

 

and Air Conditioning, Inc.

EER

--- Energy Efficiency Ratio

IEER

--- Integrated Energy Efficiency Ratio

SEER

--- Seasonal Energy Efficiency Ratio

Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org.

NOTES:

1.Rated in accordance with AHRI Standards 210/240 (04---06 size) and 340/360 (07---09 size).

2.Ratings are based on:

Cooling Standard: 80_F (27_C) db, 67_F (19_C) wb indoor air temp and 95_F (35_C) db outdoor air temp. IEER Standard: A measure that expresses cooling part---load EER efficiency for commercial unitary air---

conditioning and heat pump equipment on the basis of weighted operation at various load capacities.

3.All 581J units comply with ASHRAE 90.1 2001, 2004 Energy Standard for minimum SEER and EER requirements.

4.581J units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap---energy.org.

8

Image 8
Contents Product Data Catalog No.PDS581J---01Table of Contents Features and Benefits Model Number Nomenclature Economizer Sensors FACTORY-INSTALLED Options and FIELD-INSTALLED Accessories Economizers Factory Options AND/OR Accessories Economizer dry-bulb or enthalpyFactory Options AND/OR Accessories CON’T Motormaster Head Pressure ControllerAhri Cooling Rating -STAGE Cooling NOM NET CoolingUnit Seer EER Ieer StagesHeating Rating Table Natural GAS & Propane AL/SS Heat Exchanger Temp Rise Thermal AfueUnits EfficiencyStages Weighted Heating Rating Table LOW NOX1Sound Performance Table Unit CoolingMinimum Maximum Minimum Maximum Airflow Ratings Natural GAS & PropaneCooling Heating Minimum Tons Physical DataCooling Heat Anticipator Setting Amps Physical Data Heating581J*04A 581J*05A 581J*06A 581J*07A Gas Connection Natural Gas, Propane HeatPhysical Data Cooling 8.5 Tons581J*08D 581J*09D Gas Connection # of Gas ValvesCurbs & Weights Dimensions 581J04-06 Curbs & Weights Dimensions 581J04-06 Dimension ConditionRoof Curb Details Curbs & Weights Dimensions 581J07-09 Dimensions 581J07-09Curbs & Weights Dimensions 581J07-09 Roofcurb Unit Size Accessory CRRFCURB003A01 Options & Accessory Weights Option / Accessory WeightsApplication Data Stainless SteelApplication Data Sizing a rooftopSelection Procedure with 581J*07A EXAMPLE1 Ambient Temperature Cooling Capacities Stage Cooling Tons105 115 125 EA dB 53.4 60.6 THC Cooling Capacities Stage Cooling 581J*08D115 125 EA dB Static Pressure Adders Factory Options AND/OR Accessories EconomizerGeneral fan performance notes TonsPhase 3 TON Horizontal Supply 581J*04 PhaseFAN Performance Belt Drive TON Vertical SupplyPhase 4 TON Horizontal Supply 581J*05 PhaseFAN Performance Belt Drive 581J*05581J*06--3 PHASE--5 TON Horizontal Supply 581J*06 Phase581J*07--3 PHASE--6 TON Horizontal Supply 581J*07 PhasePhase 7.5 TON Horizontal Supply 581J*08 PhaseFAN Performance Belt DRIVEcont 581J*08581J*09 Phase 8.5 TON Horizontal Supply581J*09 Phase FAN Performance X13 Multi SPEED/TORQUE Motor581J*04A Horizontal Unit-Direct Drive 581J*04A Vertical Unit-Direct Drive581J*05A Horizontal Unit-Direct Drive 581J*05A Vertical Unit-Direct Drive581J*06A Horizontal Unit-Direct Drive 581J*06A Vertical Unit-Direct DrivePulley Adjustment PhaseECONOMIZER, Barometric Relief and PE Performance 5 TonElectrical Information 581J*04AStage Cooling Tons 581J*05AElectrical Information CON’T 581J*06A--1-STAGE COOLING--5 Tons581J*07A Stage Cooling 6 Tons581J*08D--2-STAGE COOLING--7.5 Tons 581J*09D--2-STAGE COOLING--8.5 TonsRange RLA MINMCA/MOCP MCA/MOCP Determination no C.O. or Unpwrd C.O.-3-5 TONMCA/MOCP CON’T Pwrd C.OMCA Hacr Hacr Brkr FLA LRAMCA/MOCP Determination no C.O. or Unpwrd C.O.-6-8.5 TON IFM Combust FAN PWRMotor Exhaust No P.E DISC. Size Fuse TypeCombust FAN PWR IFM Exhaus Motor No P.EFuse DISC. Size Type Hacr FLA LRA BrkrTypical Wiring Diagrams Stage Cooling Typical Power DiagramTypical Wiring Diagrams Stage Typical Wiring Diagram C08578 Heating Sequence of OperationCooling Sequence of Operation Guide Specifications 581J*04-09 Gas Heat/Electric Cooling Packaged Rooftop23 07 16 Hvac Equipment Insulation 23 09 13 Instrumentation and Control Devices for Hvac23 09 33 Electric and Electronic Control System for Hvac 23 81 19 Self-Contained Air Conditioners 23 09 93 Sequence of Operations for Hvac Controls23 40 13 Panel Air Filters 581J 581J 581J 581J 581J 581J 581J