Bryant 581J specifications Table of Contents

Page 2

581J

TABLE OF CONTENTS

 

PAGE

 

PAGE

FEATURES AND BENEFITS

. . . 3

SELECTION PROCEDURE

. . 25

MODEL NUMBER NOMENCLATURE

. . . 4

COOLING TABLES

. . 26

FACTORY OPTIONS AND/OR ACCESSORIES . .

. . . 6

STATIC PRESSURE ADDERS

. . 32

AHRI COOLING RATING TABLES

. . . 8

FAN PERFORMANCE

. . 33

HEAT RATING TABLE

. . . 9

OUTDOOR AIR INTAKE & EXHAUST PERF . . . . . 43

SOUND PERFORMANCE TABLE

. . 10

ELECTRICAL INFORMATION

. . 44

PHYSICAL DATA

. . 12

MCA/MOCP

. . 46

CURBS & WEIGHTS DIMENSIONS

. . 16

TYPICAL WIRING DIAGRAMS

. . 51

APPLICATION DATA

. . 23

SEQUENCE OF OPERATION

. . 55

 

 

GUIDE SPECIFICATIONS

. . 57

Your Bryant rooftop unit (RTU) was designed by customers for customers. With “no-strip screw” collars, handled access panels, and more we’ve made your unit easy to install, easy to maintain and easy to use.

Easy to install:

All Preferred Seriest units are field-convertible to horizontal air flow; no special adapter curbs or kits are necessary. Convertible airflow design makes it easy to adjust to unexpected job-site complications. Lighter units make easy replacement. Bryant 3-8.5 ton 581J rooftops fit on existing Bryant curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Bryant accessory controls.

Easy to maintain:

Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our “no-strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take refrigeration system pressure readings without affecting the condenser airflow.

Easy to use:

The newly designed, master terminal board by Bryant puts all your connections and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Bryant rooftops have high and low pressure switches, a filter drier, and 2” (51mm) filters standard.

the environmentally sound refrigerant

2

Image 2
Contents Product Data Catalog No.PDS581J---01Table of Contents Features and Benefits Model Number Nomenclature Economizer Sensors FACTORY-INSTALLED Options and FIELD-INSTALLED AccessoriesEconomizers Factory Options AND/OR Accessories Economizer dry-bulb or enthalpyFactory Options AND/OR Accessories CON’T Motormaster Head Pressure ControllerUnit Ahri Cooling Rating -STAGE CoolingNOM NET Cooling Seer EER Ieer StagesUnits Heating Rating Table Natural GAS & PropaneAL/SS Heat Exchanger Temp Rise Thermal Afue EfficiencySound Performance Table Stages WeightedHeating Rating Table LOW NOX1 Unit CoolingMinimum Maximum Minimum Maximum Airflow Ratings Natural GAS & PropaneCooling Heating Minimum Tons Physical DataCooling 581J*04A 581J*05A 581J*06A 581J*07A Gas Connection Heat Anticipator Setting AmpsPhysical Data Heating Natural Gas, Propane HeatPhysical Data Cooling 8.5 Tons581J*08D 581J*09D Gas Connection # of Gas ValvesCurbs & Weights Dimensions 581J04-06 Curbs & Weights Dimensions 581J04-06 Dimension ConditionRoof Curb Details Curbs & Weights Dimensions 581J07-09 Dimensions 581J07-09Curbs & Weights Dimensions 581J07-09 Roofcurb Unit Size Accessory CRRFCURB003A01 Options & Accessory Weights Option / Accessory WeightsApplication Data Stainless SteelApplication Data Sizing a rooftopSelection Procedure with 581J*07A EXAMPLE1 Ambient Temperature Cooling Capacities Stage Cooling Tons105 115 125 EA dB 53.4 60.6 THC Cooling Capacities Stage Cooling 581J*08D115 125 EA dB General fan performance notes Static Pressure Adders Factory Options AND/OR AccessoriesEconomizer TonsFAN Performance Belt Drive Phase 3 TON Horizontal Supply581J*04 Phase TON Vertical SupplyFAN Performance Belt Drive Phase 4 TON Horizontal Supply581J*05 Phase 581J*05581J*06--3 PHASE--5 TON Horizontal Supply 581J*06 Phase581J*07--3 PHASE--6 TON Horizontal Supply 581J*07 PhaseFAN Performance Belt DRIVEcont Phase 7.5 TON Horizontal Supply581J*08 Phase 581J*08581J*09 Phase 8.5 TON Horizontal Supply581J*09 Phase 581J*04A Horizontal Unit-Direct Drive FAN PerformanceX13 Multi SPEED/TORQUE Motor 581J*04A Vertical Unit-Direct Drive581J*05A Horizontal Unit-Direct Drive 581J*05A Vertical Unit-Direct Drive581J*06A Horizontal Unit-Direct Drive 581J*06A Vertical Unit-Direct DrivePulley Adjustment PhaseECONOMIZER, Barometric Relief and PE Performance 5 TonStage Cooling Tons Electrical Information581J*04A 581J*05A581J*07A Electrical Information CON’T581J*06A--1-STAGE COOLING--5 Tons Stage Cooling 6 TonsRange RLA 581J*08D--2-STAGE COOLING--7.5 Tons581J*09D--2-STAGE COOLING--8.5 Tons MINMCA/MOCP MCA/MOCP Determination no C.O. or Unpwrd C.O.-3-5 TONMCA Hacr MCA/MOCP CON’TPwrd C.O Hacr Brkr FLA LRAMotor Exhaust No P.E MCA/MOCP Determination no C.O. or Unpwrd C.O.-6-8.5 TONIFM Combust FAN PWR DISC. Size Fuse TypeFuse DISC. Size Type Combust FAN PWRIFM Exhaus Motor No P.E Hacr FLA LRA BrkrTypical Wiring Diagrams Stage Cooling Typical Power DiagramTypical Wiring Diagrams Stage Typical Wiring Diagram C08578 Heating Sequence of OperationCooling Sequence of Operation 23 07 16 Hvac Equipment Insulation Guide Specifications 581J*04-09Gas Heat/Electric Cooling Packaged Rooftop 23 09 13 Instrumentation and Control Devices for Hvac23 09 33 Electric and Electronic Control System for Hvac 23 81 19 Self-Contained Air Conditioners 23 09 93 Sequence of Operations for Hvac Controls23 40 13 Panel Air Filters 581J 581J 581J 581J 581J 581J 581J
Related manuals
Manual 40 pages 41.76 Kb