Powermate PC0102300 manual Periodic Maintenance

Page 9

PERIODIC MAINTENANCE

ITEM

NOTES

Daily (Before

Initial

Every

Every

operation)

20 hours

50 hours

100 hours

 

 

 

 

 

 

 

 

Spark Plug

Check condition. Adjust gap and

 

 

ü

 

clean. Replace if necessary.

 

 

 

Engine Oil

Check oil level.

ü

 

 

 

 

Replace.

 

ü

 

ü

Air Filter

Clean, replace if necessary.

 

 

ü

 

Fuel Filter

Clean fuel filter and fuel tank strainer.

 

 

 

ü

Replace if necessary.

 

 

 

Fuel Line

Check fuel hose for cracks or other

ü

 

 

 

damage. Replace if necessary.

 

 

 

Exhaust

Check for leakage. Retighten or

ü

 

 

 

System

replace gasket if necessary.

 

 

 

 

Check muffler screen. Clean/replace

 

 

 

ü

 

if necessary.

 

 

 

Carburetor

Check choke operation.

ü

 

 

 

Starting

Check recoil starter operation.

ü

 

 

 

System

 

 

 

Fittings/

Check. Replace if necessary.

 

 

 

ü

Fasteners

 

 

 

MAINTENANCE

SPARK PLUG

Remove the spark plug and clean the electrodes section with a wire brush or sandpaper. Next, set the gap at .028/.031 inches (0.7-0.8 mm) by adjusting the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m)

Replace with only the same type of spark plug which was removed. An improper spark plug can cause the engine to overheat, emit smoke, or otherwise perform poorly.

OIL TYPE

Use new good quality oil, SE, SF, or SD grade. The oil to be used depends upon the temperature at which the engine is operated:

Below 32° F (0° C) . . . . . . . . .SAE 10W, 10W-30, or 10W-40 32 to 80° F (0 to 25° C) . . . . . .SAE 20W, 10W-30, or 10W-40 80 to 95° F (25 to 35° C) . . . . .SAE 30W, 10W-30, or 10W-40 Above 95° F (35° C) . . . . . . . . . . . . . . . . . . . . . . . . .SAE 40W

OIL REPLACEMENT

1.Change oil while engine is warm.

2.Place the generator unit on a level surface.

3.Remove the oil filler cap.

4.Open the oil drain plug and let oil drain completely into a pan placed under the engine.

5.Check gaskets. Replace if required.

6.Reinstall the oil drain plug and refill engine with clean oil.

7.Replace the oil filler cap.

AIR FILTER CLEANING

1.Unscrew the air filter cover.

2.Remove filter element and wash well in solvent.

3.Pour a small amount of oil onto the filter element and gently squeeze out any excess oil.

4.Replace the filter element and air filter cover.

5.Be sure the filter cover seals properly all around.

FUEL VALVE FILTER CLEANING

1.Remove the cup at the bottom of the fuel valve with a small wrench.

2.Remove the fuel valve filter.

3.Clean and wash out the filter and cup and replace.

FUEL STRAINER CLEANING

1.Remove the plastic fuel strainer, located below the fuel tank cap.

2.Wash the strainer in solvent and replace.

English

 

9

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Image 9
Contents Alto StopTable of Contents Table DES MatieresIndice Safety and Operation Rules Spark Arrester Determining Total WattageKW = 1,000 watts Operating Voltage InstallationGrounding the Generator Before OperationLOW OIL Sensor FuelGenerator Features PRE-START Preparation Starting the UnitStarting the Engine Applying LoadMaintenance Periodic MaintenanceInfrequent Service Service and StorageExciting the Generator Heat ShieldEngine Troubleshooting Engine Specifications Powermate Corporation Airport Road Box Kearney, NE Service Information Limited WarrantyRègles D’OPÉRATION ET DE Sécurité Voire la mortDétermination DE LA Puissance Totale Nécessaire PARE-ÉTINCELLESVérifier LA Tension Mise EN Place DE Lappareil Avant DE Mettre EN MarcheCarburant LubrificationTableau de commande Prise de 120 V, 20 a Caractéristiques DU Groupe ElectrogeneDisjoncteurs Préparatifs AU Démarrage Demarrage DE LappareilBranchement DES Appareils Démarrage DU MoteurEntretien Entretien PériodiqueLA Bougie D’ALLUMAGE LE Type D’HUILEUsage ET Entreposage Depannage DU Moteur Caracteristiques DU Moteur Service Clientele Commande DE Pièces DE RechangeGarantie Limitée Seguridad Reglas DE Seguridad Y DE FuncionamientoComo Determinar EL Vataje Total ApagachispasEL Requerimiento DE Voltaje InstalacionPuesta a Tierra DEL Generador Antes DE LA OperacionCombustible LubricacionCaracteristicas DEL Generador Panel de control Receptáculo de 120 voltios, 20 amperesInterruptor Preparacion Antes DE Arrancar Arranque DEL UnidadArranque DEL Motor Como Aplicar UNA CargaMantenimiento Mantenimiento PeriódicoBujia Tipo DE AceiteExcitacion DEL Generador Servicio Y AlmacenamientoEscudo DE Calor Servicio Poco FrecuenteDeteccion DE Fallos DEL Motor Especificaciones DEL Motor Como Pedir LOS Repuestos Servicio AL Cliente Garantía LimitadaParts Drawing / Schema DES Pièces / Diagrama DE Piezas Part Description Descripción Parts List / Liste DES Pièces / Lista DE PiezasCustomer Hotline Powermate Corporation