Multiquip TP7X operation manual Water pump maintenance, Belt Replacement, Bearing housing removal

Page 26

MAINTENANCE

Water pump maintenance

When the machine has not been used for a long period of time, hard packed dirt may build up inside the pump and block the pump wheel.

NOTICE

If the machine is activated with the immersion pump blocked, the electric motor will be damaged within a few minutes!

Please follow the steps below to clean the pump before operating the saw.

1.Remove the immersion pump from the water container.

2.Clean the immersion pump.

3.Loosen the fixing screws of the pump lid.

4.Take the lid off the pump (be careful not to damage or lose the gasket underneath)

5.Clean the pump lid.

6.Remove all dirt and incrustations from the pump wheel.

7.Check whether the pump wheel can be easily turned.

8.Reassemble the immersion pump and check that it works properly.

Belt Replacement

To replace the belt (Figure 18) perform the following.

1.Turn off and unplug the saw.

2.Loosen and remove the belt guard sccrews and take off the belt guard.

3.Loosen the 6 nuts on the cutting head’s supporting arm.

4.Leave the blade in position, and use your hand to hold the blade shaft tightly. Now loosen the pulley lock screw on the rear of the motor pulley shaft.

5.Carefully loosen the pulley and belt outward slightly, so there is a little slack in the belt.

6.Take off the old belt and replace with a new one.

7. To reassemble, follow steps in reverse order.

Figure 18. Belt Replacement

CUTTING HEAD REMOVAL

To remove the cutting head, see Saw Set-Up and Figure 4 and perform the steps in reverse.

Bearing housing removal

To remove the bearing housing (Figure 19), perform the following:

1.Follow steps 1-6 of the Belt Replacement Section.

2.Remove the blade lock nut and remove the blade (if there is one present.)

3.Remove the precaution label and loosen the 4 screws at the front of the cutting head. Remove the bearing housing and inner flange.

page 26 — TP7X TILE SAW • operation manual — rev. #0 (03/04/11)

Image 26
Contents Model TP7X Proposition 65 Warning Silicosis/Respiratory Warnings Silicosis WarningSawing Guides Table of ContentsSpecifications are subject to change without notice Page Safety Information SaFeTy meSSageSGeneraL SaFeTy SaW SaFeTy BLaDe SaFeTyLIFTIng SaFeTy ELeCTrIC moTor SaFeTyPower Cord/Cable Safety TranSporTIng SaFeTySaw Specifications Electric Motor SpecificationsDimensions DimensionGeneral information Accessories/Replacement PartsFeatures Dry Cutting ApplicationsPage Saw components Saw ComponentsStopper Place stopper in water tray when filling with water Electric Motor Components Support Stand Assembly OptionalElectric motor components/set-up Saw Set-UpSet-up Connecting the water PumpInstall drain plug in water tray Refer to FigureCutting Depth BladesBlade Components Blade Diameter vs. Cutting DepthProper Blade Use Blade InstallationSee for proper blade use guidelines Using the MasterGuide Template Base Connecting the PowerSawing Guides Using the Cutting Table Set-up/sawing guidesPerforming Diagonal Cuts Using the Rip GuideSawing guides Performing Miter CutsStarting or attempting to operate the saw Start-up ProcedureOperation Shut down Procedure Wait for the cutting blade to stop rotatingBasic Maintenance Inspect the cutting table periodically. Replace worn partsBefore not using the machine for a prolonged period of time Maintenance intervalsAfter wet cleaning and before using the machine again After not using the machine for a prolonged period of timeBearing housing removal Water pump maintenanceBelt Replacement Bearing Housing Installation Bearing Housing RemovalWiring diagram electric motor Electric Motor Wiring DiagramPage Troubleshooting blade Blade TroubleshootingTroubleshooting Saw Saw TroubleshootingHERE’S HOW to GET Help