Multiquip DCA125SSIU manual Generator START-UP Procedure Auto Mode, Starting Auto Mode

Page 36

GENERATOR START-UP PROCEDURE (AUTO MODE)

STARTING (AUTO MODE)

DANGER

Before connecting this generator to any

building’s electrical system, a licensed electrician must install an isolation (transfer) switch. Serious damage to

the building’s electrical system may occur without this transfer switch.

CAUTION

When connecting the generator to a isolation (transfer) switch, ALWAYS have power applied to the generator’s internal battery charger.This will ensure that the engine will not fail due to a dead battery.

NOTICE

When the generator is set in the AUTO mode, the generator will automatically start in the event of commercial power falling below a prescribed level by means of a contact closure that is generated automatically by a transfer switch.

WARNING

When running the generator in the AUTO mode, remember the generator can start up at any time without warning. NEVER attempt to perform any maintenance when the generator is in the auto mode.

CAUTION

The engine speed switch must be set to the “High” position when running in the auto-startmode. Failing to set the switch in the proper position can result in damage to your generator when it turns on.

NOTICE

When the MPEC control switch is placed in the AUTO position, the engine glow plugs will be warmed and the engine will start automatically.

When starting generator in AUTO mode use the “Manual Start-up” procedure except where noted (see below).

1.Perform steps 1 through 5 in the Before Starting section as outlined in the Manual Starting Procedure.

2.Place the engine speed switch (Figure 51) in the HIGH position

Figure 51. Engine Speed Switch (High)

3.Place the MPEC Control Switch (Figure 52) in the AUTO position.

Figure 52. MPEC Control Switch (AUTO)

4.Continue operating the generator as outlined in the Manual Start-up procedure (start at step 5).

PAGE 36 — DCA125SSIU 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (12/22/08)

Image 36
Contents Model DCA125SSIU This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects AdministratorTable of Contents DCA125SSIU GeneratorParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Generator Safety Always know the location of the nearest Engine Safety Before servicing equipmentFuel Safety Towing SafetyElectrical Safety Grounding SafetyPower Cord/Cable Safety  The electrical voltage required toBattery Safety Environmental SafetySpecifications Generator SpecificationsDimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Assembly Major ComponentsGenerator Control Panel Owing from the U,V, and W Output Terminal Lugs to the loadPage Engine Operating Panel Engine Operating PanelEngine Speed Switch This switch controls the speed Fuel Gauge Indicates amount of diesel fuel availableOutput Terminal Panel Familiarization Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles 200V Twist-Lock Auxiliary ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Voltage Selector Switch Voltage Selector Switch Locking ButtonGenerator Outputs Generator Output VoltagesGenerator OUTPUTS/GAUGE Reading Reading VoltageReading Amperage Output Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-220/127 Uvwo Terminal Output Voltages 3Ø-200V/1Ø-115V Uvwo Terminal Output Voltages3Ø-440/254V Uvwo Terminal Output Voltages 1Ø-200/100V Uvwo Terminal Output VoltagesINSPECTION/SETUP Circuit BreakersLubrication OIL Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator AIR Cleaner FAN Belt TensionCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorGenerator START-UP Procedure Manual Place the engine speed switch in the LOW down positionBefore Starting Starting ManualFrequency Meter Generator START-UP Procedure Auto Mode Starting Auto ModeBefore connecting this generator to any Place the engine speed switch in the High positionGenerator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyMaintenance General Inspection AIR CleanerAir Cleaner with Dust Indicator Fuel Addition Fuel Tank InspectionAIR Removal Radiator Cleaning Check OIL LevelReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesHydraulic Surge Brakes ActuatorTIRES/WHEELS/LUG Nuts Tire Wear/InflationSuspension Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram CB1Engine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Troubleshooting Engine Controller Troubleshooting Diagnostic Lamp Method of OperationSample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy C0110001002 81310700138131611014 8131015003Control BOX Assy M3213001702 03300002100330000280 0330000180Control BOX Assy 0027106016 58255002908970119490 M3213500604Control BOX Assy 0027105010 M92201000040080200007 0602122272Engine and Radiator Assy M3923200134 8980527130M3303200603 0010310025Engine and Radiator Assy 0602021070 0269200600M3323500004 0016910025Output Terminal Assy M3230700003 M9220100304M9220100404 0039316000Battery Assy 0602220198 M9310500404M9103000504 0602220921Muffler Assy M3330100902 M33330014031141451840 M3333200004Fuel Tank Assy M3363002002 06055050700605501076 0605516090Enclosure Assy M3413002402 M1413400004M3423002702 M3493114303Enclosure Assy M3443200703 M34436001040037906000 36A 0041206000Enclosure Assy 0600800320 M345370000466A M9116100004 M9110100304Rubber Seals Assy 0229201100 02289008800228900990 0228901050Nameplate and Decals Assy M3550003003 M35000300AM9520100304 M92010030Nameplate and Decals Assy M9500500004 M9500500104M9510200002 060050090Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help
Related manuals
Manual 90 pages 9.4 Kb

DCA125SSIU specifications

The Multiquip DCA125SSIU is a robust and versatile diesel generator that is designed to meet the power needs of various applications, from construction sites to events and emergency situations. With a power output of 125 kVA, this generator combines efficiency and reliability, making it an ideal choice for professionals who demand optimal performance in challenging environments.

One of the primary features of the DCA125SSIU is its industrial-grade a diesel engine. This engine not only delivers impressive power but also emphasizes fuel efficiency. The generator is equipped with advanced fuel management technologies that help minimize consumption while maximizing output, making it cost-effective for long-term use.

In terms of durability, the DCA125SSIU is built with a sturdy enclosure that protects it from environmental factors. The weather-resistant design ensures that it operates effectively in a variety of weather conditions, ensuring reliable performance when needed the most. Additionally, its compact size allows for easy transport and storage, which is particularly beneficial for contractors and rental companies.

The DCA125SSIU features a user-friendly control panel that provides essential information at a glance. This panel includes gauges for monitoring key parameters such as voltage, frequency, and hours of operation. It also has an automatic voltage regulator (AVR) that maintains consistent voltage output, safeguarding connected equipment from potential damage caused by power fluctuations.

Safety is a priority with the DCA125SSIU, as it is equipped with several emergency shutdown features. These include low oil pressure, high temperature, and overload protection, ensuring that the generator operates safely under all conditions. Further enhancing its operational reliability, the generator comes with a built-in fuel tank that allows for extended runtime, reducing the frequency of refueling during use.

In summary, the Multiquip DCA125SSIU is a powerful, durable, and efficient diesel generator that meets the diverse power needs of various industries. Its combination of a high-performance engine, user-friendly control panel, robust safety features, and fuel efficiency makes it an exceptional choice for anyone looking for a reliable power solution. Whether for temporary power during events, backup for critical systems, or support at construction sites, the DCA125SSIU is engineered to perform.