Table 10 - Dry Coil Air Delivery* - Horizontal and Downflow Discharge - Unit 677C--A24-60 Cont

UNIT

HEATING

MOTOR

WIRE

 

 

 

EXTERNAL STATIC PRESSURE (in. W.C.)

 

 

RISE

SPEED

COLOR

 

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

 

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1448

1362

1296

1226

1168

1108

1071

998

905

 

 

 

 

Heating

60

NA

NA

NA

NA

NA

NA

NA

NA

 

 

Low

Blue

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

33

NA

NA

NA

NA

NA

NA

NA

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1722

1675

1614

1543

1499

1442

1408

1356

1308

 

 

 

 

Heating

50

52

54

56

58

60

NA

NA

NA

 

 

Med-Low

Pink

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

28

29

30

31

32

33

NA

NA

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1887

1847

1783

1726

1677

1625

1578

1527

1432

 

30 - 60oF

 

 

Heating

46

47

49

50

52

53

55

57

NA

677C --- ---A60115

Medium2

Red

Rise (oF)

(17 - 33oC)

 

 

 

 

 

 

 

 

 

 

 

 

Heating

26

26

27

28

29

30

31

32

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

2055

2008

1958

1927

1900

1768

1685

1581

1458

 

 

 

 

Heating

42

43

44

45

46

49

52

55

60

 

 

Med-High1

Orange

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

23

24

25

25

25

27

29

31

33

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

2292

2238

2158

2049

1935

1840

1732

1635

1513

 

 

 

 

Heating

38

39

40

42

45

47

50

53

57

 

 

High

Black

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

21

22

22

24

25

26

28

30

32

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1448

1321

1282

1235

1192

1145

1101

1057

1011

 

 

 

 

Heating

NA

NA

NA

NA

NA

NA

NA

NA

NA

 

 

Low

Blue

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

NA

NA

NA

NA

NA

NA

NA

NA

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1722

1675

1614

1543

1499

1442

1408

1356

1308

 

 

 

 

Heating

56

57

60

62

64

NA

NA

NA

NA

 

 

Med-Low

Pink

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

31

32

33

35

36

NA

NA

NA

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1887

1847

1783

1726

1677

1625

1578

1527

1432

 

35 - 65oF

 

 

Heating

51

52

54

56

57

59

61

63

NA

677C --- ---A60130

Medium2

Red

Rise (oF)

(19 - 36oC)

 

 

 

 

 

 

 

 

 

 

 

 

Heating

28

29

30

31

32

33

34

35

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

2055

2008

1958

1927

1900

1768

1685

1581

1458

 

 

 

 

Heating

47

48

49

50

51

54

57

61

NA

 

 

Med-High1

Orange

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

26

27

27

28

28

30

32

34

NA

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

2292

2238

2158

2049

1935

1840

1732

1635

1513

 

 

 

 

Heating

42

43

45

47

50

52

56

59

64

 

 

High

Black

Rise (oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating

23

24

25

26

28

29

31

33

35

 

 

 

 

Rise (oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

*Air delivery values are without air filter and are for dry coil (See 677C --- ---A Wet Coil Pressure Drop table).

1 Factory ---shipped gas heating speed

2 Factory ---shipped heat pump speed NA --- Not allowed for heating speed

Note: Deduct field---supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed.

677C-- -- A

23

Image 23
Contents Safety Considerations Table of ContentsIntroduction Receiving and Installation677C--A24-30 Unit Dimensions 677C--A36-60 Unit Dimensions CPRFCURB012A00 Unit SizeCPRFCURB010A00 CPRFCURB011A00Rigging/Lifting of Unit See Fig Rig and Place UnitInspection Carbon Monoxide Poisoning Hazard Install Flue HoodInstall Gas Piping Connect Condensate DrainFire or Explosion Hazard Install Duct ConnectionsConfiguring Units for Downflow Vertical Discharge Furnace Section CompressorsRefrigerant Metering CFMHeating Inputs Physical Data Unit 677C--A Cont’dMaximum Gas Flow Capacity Control Voltage Connections Install Electrical ConnectionsSpecial Procedures for 208-V Operation High-Voltage ConnectionsFIRE, EXPLOSION, Electrical Shock Hazard Balance Point Setting-Thermidistat or Hybrid ThermostatPRE-START-UP Transformer ProtectionUnit Sequence of Operation Start-up Heating and Make Adjust- mentsSTART-UP Check for Refrigerant LeaksUnit Damage Hazard Adjust Gas InputCheck Heating Control Check Gas InputNormal Operation Airflow and Temperature RiseLimit Switches Check Burner FlameIndoor Airflow and Airflow Adjustments Start-up Cooling and Make Adjust- mentsRollout Switch Checking and Adjusting Refrigerant ChargeColor Coding for Indoor Fan Motor Leads Two Cooling Fan Speeds Set-up Dehumidification feature usedGas Heating Fan Speed Set-up Continuous Fan OperationFilter Size CFM 677C--A Wet Coil Pressure DropRise Speed Color Range Unit Heating Motor Wire1505 1452 1413 1358 1323 1282 1234 1169 1130 25 55oF Heating 1962 1915 1880 1843 1794 1753 1711 1675 1628 35 65oF Heating 1962 1915 1880 1843 1794 1753 1711 1675 1628 30 60oF Heating 1887 1847 1783 1726 1677 1625 1578 1527 1432 30 60oF Heating 677C a 208/230-3-60 Wiring Diagram, Unit 677C--A Cooling Charging Table-Subcooling Indoor Blower and Motor MaintenanceCleaning the Blower Motor and Wheel Air FilterFlue Gas Passageways Limit SwitchInduced Draft combustion air Blower Assembly Burner IgnitionEXPLOSION, Personal Injury and Environmental Hazard Electrical Controls and WiringOutdoor Fan Refrigerant CircuitIndoor Airflow Pressure SwitchesLoss of Charge Switch Gas InputExplosion Hazard High-Pressure SwitchCopeland Scroll Compressor Puron Refrigerant Servicing Systems on Roofs and with Synthetic materials Unit Operation and Safety HazardRefrigerant System Compressor OilPuronr R-410A Quick Reference Guide TroubleshootingSTART-UP Checklist Symptom Cause Remedy Troubleshooting Guide Cooling or Heat Pump Heating ModeLED OFF Troubleshooting Guide-HeatingTroubleshooting Guide-LED Status Codes III. START-UP Electrical Supply Voltage Compressor Amps TemperaturesRemove and Store in Job Files Preliminary Information Model no