Grounding

 

Extension Cords

 

 

 

 

 

 

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment grounding conductor. A plug with a grounding pin must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper connections of the electrical-grounding conductor can result in risk of electric shock. The conductor with green or green and yellow striped insulation is the electrical grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.

This equipment must be grounded. Verify that any existing electrical outlet and circuit you intend to plug into is actually grounded. Under no cir- cumstances should the grounding pin from any three-pronged plug be removed. Serious injury may occur.

Under no circumstances should the grounding pin from any plug be removed. If it will not fit the outlet, have the proper outlet installed by a quali- fied electrician. Repair or replace damaged or worn cords immediately.

Check with a qualified electrician or one of our service personnel if the grounding instructions are not completely understood, or if you are in doubt as to whether the tool is properly grounded. Use only extension cords that have grounding type plugs and receptacles that accept the plug on the machine.

We do not recommend the use of extension cords on 220V or 440V equipment. It is much bet- ter to arrange the placement of your equipment and the installed wiring to eliminate the need for extension cords. Should it be necessary to use an extension, make sure the cord is rated Hard Service (Grade S) or better. Refer to the chart on page 3 to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

We have covered some basic electrical requirements for the safe operation of your bandsaw. These requirements are not nec- essarily comprehensive. You must be sure that your particular electrical configuration complies with local and state codes. Ensure compliance by checking with your local municipality or a licensed electrician.

24" & 27" Resaw Bandsaws

-7-

Image 9
Contents Models G3619/G3620/G9963/G9966 Resaw BandsawsPage Table Of Contents Safety Instructions For Power Tools SafetyLength AMP Rating Additional Safety Instructions For Bandsaws Model G3619 Model G9963 Circuit RequirementsModel G3620/G9966 440V Operation Typical plug configuration for Three-phase operationGrounding Extension Cords Commentary General InformationUnpacking Piece Inventory Site Considerations Clean UpBeginning AssemblyTo install the dust port Fence Dust PortTo mount the fence Identification AdjustmentsBlade Guides Guide PostG9963/G9966 Blade Guides G3619/G3620 Blade GuidesG9963/G9966 Tracking G3619/G3620 TrackingTo center track your blade To track the bladeTo adjust the support bearings behind the blade Support BearingsTo center the support bearings laterally Guide Blocks Blade Guard Table Stop To center the blade guardMake sure the bandsaw is unplugged Table Tilt To tilt the table Disconnect power to the bandsawTo adjust the tension Test RunBlade Tension To adjust the fence so it is parallel with the blade Fence Adjustment Blade LeadBlade Selections OperationsBlade Length Blade WidthTooth Pitch Blade CareBlade Breakage Blade Changes Ripping Stacked Cuts To perform ripping operationsTo complete a stacked cut Resawing To resaw lumber, follow the procedure belowBelts MaintenanceMiscellaneous LubricationPage Page 24 & 27 Resaw Bandsaws 24 & 27 Resaw Bandsaws Closure Machine Data Sheet G3619/G3620 G3619/G3620 G3619/G3620 G3619/G3620 G3619/G3620 Frame Fence Rail Grizzly Model G9963/G9966 27 Bandsaw G9963/G9966 Arin g C o G9963/G9966 189 24 & 27 Resaw Bandsaws 8026 Hinge PIN Support Bearing Troubleshooting Warranty and Returns Warranty Card BOX BELLINGHAM, WA Grizzly INDUSTRIAL, INC