SECTION 2: CIRCUIT REQUIREMENTS
220V Operation |
| 110V Operation |
|
|
|
|
|
|
The Model G1073/G1073Z Bandsaw is supplied with a
The Model G1073/G1073Z Bandsaw is not sup- plied with a power plug. We recommend using a
Figure 1. Typical 220V 3-prong plug and outlet.
Be sure that your particular electrical config- uration complies with local and state codes. The best way to ensure compliance is to check with your local municipality or licensed electrician.
If 110 volt operation is desired, refer to the wiring diagram in the back of this manual. Under normal use, the motor draws approximately 24 amps at 110V. We recommend using a circuit breaker and wires rated for 30 amps. This should be satisfac- tory for normal use, while providing enough pro- tection against damage caused by power surges. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.
The Model G1073/G1073Z is not supplied with a power plug. It will be necessary to supply your own standard 110V, 30 Amp grounded plug and receptacle as shown in Figure 2.
Extension Cords
We do not recommend the use of extension cords on 220V equipment. It is much better to arrange the placement of your equipment and the installed wiring to eliminate the need for exten- sion cords. Should it be necessary to use an extension, make sure the cord is rated Hard Service (Grade S) or better. Refer to the chart on page 3 to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.
G1073/G1073Z 16'' Bandsaw |