SECTION 2: CIRCUIT REQUIREMENTS

220V Operation

 

110V Operation

 

 

 

 

 

 

The Model G1073/G1073Z Bandsaw is supplied with a dual-voltage 110V/220V motor, prewired for 220V operation. Under normal use, the motor draws approximately 12 amps at 220V. We rec- ommend a 15 amp circuit breaker or slow-blow fuse for 220V. This should be satisfactory for nor- mal use, while providing enough protection against damage caused by an overloaded circuit. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

The Model G1073/G1073Z Bandsaw is not sup- plied with a power plug. We recommend using a NEMA-style L6-15 plug and outlet similar to the one shown in Figure 1. You may also Òhard-wireÓ the bandsaw directly to your panel, provided you place a disconnect near the machine.

Figure 1. Typical 220V 3-prong plug and outlet.

Be sure that your particular electrical config- uration complies with local and state codes. The best way to ensure compliance is to check with your local municipality or licensed electrician.

If 110 volt operation is desired, refer to the wiring diagram in the back of this manual. Under normal use, the motor draws approximately 24 amps at 110V. We recommend using a circuit breaker and wires rated for 30 amps. This should be satisfac- tory for normal use, while providing enough pro- tection against damage caused by power surges. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

The Model G1073/G1073Z is not supplied with a power plug. It will be necessary to supply your own standard 110V, 30 Amp grounded plug and receptacle as shown in Figure 2.

Extension Cords

We do not recommend the use of extension cords on 220V equipment. It is much better to arrange the placement of your equipment and the installed wiring to eliminate the need for exten- sion cords. Should it be necessary to use an extension, make sure the cord is rated Hard Service (Grade S) or better. Refer to the chart on page 3 to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

G1073/G1073Z 16'' Bandsaw

-5-

Image 7
Contents Model G1073/G1073Z BandsawPage Table Of Contents Safety Instructions For Power Tools SafetyLength AMP Rating Additional Safety Instructions For Bandsaws 220V Operation 110V Operation Circuit RequirementsExtension Cords Grounding General Information Hardware Qty Unpacking Piece InventoryClean up Site Considerations Stand G1073 AssemblyTo assemble the stand Bandsaw To Stand To install the V-belt Wiring The Motor BeltMotor Mount Bolts To mount the table and trunnion support Working TableTo mount the rails FenceThere are two ways to remove the fence To mount the dust port Guard Dust PortBlade Tracking AdjustmentsTo adjust the tension Blade TensionEccentric blade support Blade GuidesGuide Blocks Table StopTo tilt the table Table ParallelismTable Tilt To position the blade line parallel to the miter slotBlade Changes Guide Post To adjust the guide post bracketTo check guide post alignment To adjust the rear clamping pressure Fence AdjustmentTo shift the blade To skew your fence Blade LeadTo verify if the the upper and lower wheels are coplanar Wheel AlignmentShimming a wheel Adjusting Parallelism Test Run OperationsBlade Selections To resaw lumber Table Adjustment sectionCutting Curves ResawingMiscellaneous MaintenanceV-belt is accessed via the bottom cover BeltsClosure G1073/G1073Z 16 Bandsaw Model G1073/G1073Z 16 Bandsaw 104 111A 129A 128 108-1 127 81C 126 174 190 108165 130A 139 95A 117Ł 13A 138 137A 136 135 G1073/G1073Z 16 Bandsaw 184 Model Model 1073Z Main Body Casting PSB07 Troubleshooting Warranty and Returns Warranty Card BOX BELLINGHAM, WA Grizzly INDUSTRIAL, INC