Grizzly G1019 instruction manual Right Angle Brace

Page 14

6.Attach the right angle brace to the bottom of the top panel using (2) 516''-18 x 12'' carriage bolts, (2) flat washers and (2) hex nuts. Finger tighten only. See Figure 8.

8.Place the drive pulley on the motor shaft and line up the keyways. Insert the key and tighten down the pulley setscrew. See

Figure 10.

Right

Angle

Brace

Figure 8. Attach right angle brace.

7.Install the top panel using (10) 516''-18 x 12'' carriage bolts, (10) flat washers and (10) hex nuts. It may be necessary to wiggle the panels a bit to line up the bolt holes. Finger tighten only. See Figure 9.

Top

Panel

Figure 9. Install top panel.

Drive Pulley

Figure 10. Drive pulley placed on shaft.

9.Lay the stand on its side. Carefully set the motor on the motor bracket (see Figure 11) and line up the holes. Secure the motor using (4) 516''-18 x 1'' hex bolts, (4) hex nuts and (8) flat washers, finger tight only. Slide the motor to the top of the stand as far as it will go. Tighten the top two motor bolts down leaving the bottom two finger tight. Set the stand upright at this time.

Figure 11. Place drive pulley.

-12-

G1019 14'' Bandsaw

Image 14
Contents Bandsaw Page Table Of Contents Safety Safety Instructions For Power ToolsAMP Rating Additional Safety Instructions For Bandsaws Circuit Requirements 110V Operation 220V OperationExtension Cords Grounding General Information CommentaryUnpacking Piece InventoryClean up Site ConsiderationsAssembly StandCross Braces Right Angle Brace Switch Connecting switch to motor G1019 14 BandsawBandsaw To Stand Belt Aligning pulleys with plumb bob G1019 14 BandsawStand Guards Guard case in placeStar knobs Dust Port FenceBlades Fence in positionAdjustments Location Of ControlsBlade Tension Location of blade controlsBlade Tracking Blade GuidesTable Adjustments Support BearingsPage Fence Adjustment Blade Lead Test Run Operations GeneralBlade Information Changing BladesRipping Side and front views of a standard Bandsaw bladeStacked Cuts Cutting Curves Minimum circle radius vs. blade size G1019 14 BandsawCircle Cut Attachment Resawing Maintenance GeneralBearingsClosure Wiring Diagram Machine Data Sheet Troubleshooting Symptom Possible Cause Corrective ActionG1019 14 Bandsaw G1019 14 Bandsaw G1019 14 Bandsaw 01 P1019001A Upper Frame ARM Motor Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC