Grizzly G1019 instruction manual Blade Lead Test Run

Page 27

Blade Lead

Test Run

Blade lead occurs when you are attempting a straight cut and the blade wanders to one side or the other. It is an inherent situation with all band- saws and often occurs when using the fence. The reason this usually happens is (1) the blade ten- sion isn’t correct, (2) the teeth are dull on one side, or (3) the teeth are heavier on one side of the blade than the other.

If you don’t have time to switch blades or readjust your bandsaw, you can temporarily compensate for blade lead by slightly rotating your table. To do this, rotate the table to match the angle that your blade is leading. Your purpose in doing this is to “trick” your bandsaw into cutting straight.

Once assembly is complete, adjustments are done to your satisfaction and tools are safely put away, you are ready to test run the machine.

Turn on the power supply at the main panel. Press the START button on the switch. Make sure that your finger is poised on the switch to press the STOP button in case there’s a problem. The bandsaw should run smoothly, with little or no vibration or rubbing noises. Strange or unnatural noises should be investigated and corrected before operating the machine further.

If you cannot easily locate the source of an unusual noise or vibration, contact our Service Department for help.

G1019 14'' Bandsaw

-25-

Image 27
Contents Bandsaw Page Table Of Contents Safety Instructions For Power Tools SafetyAMP Rating Additional Safety Instructions For Bandsaws 110V Operation 220V Operation Circuit RequirementsExtension Cords Grounding Commentary General InformationPiece Inventory UnpackingSite Considerations Clean upStand AssemblyCross Braces Right Angle Brace Connecting switch to motor G1019 14 Bandsaw SwitchAligning pulleys with plumb bob G1019 14 Bandsaw Bandsaw To Stand BeltGuard case in place Stand GuardsStar knobs Fence Dust PortFence in position BladesLocation Of Controls AdjustmentsLocation of blade controls Blade TensionBlade Guides Blade Tracking Support Bearings Table AdjustmentsPage Fence Adjustment Blade Lead Test Run General OperationsChanging Blades Blade InformationSide and front views of a standard Bandsaw blade RippingMinimum circle radius vs. blade size G1019 14 Bandsaw Stacked Cuts Cutting CurvesCircle Cut Attachment Resawing GeneralBearings MaintenanceClosure Wiring Diagram Machine Data Sheet Symptom Possible Cause Corrective Action TroubleshootingG1019 14 Bandsaw G1019 14 Bandsaw G1019 14 Bandsaw 01 P1019001A Upper Frame ARM Motor Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC