SECTION 7: MAINTENANCE

GeneralBearings

Regular periodic maintenance on your Model G1019 Bandsaw will ensure its optimum perfor- mance. Make a habit of inspecting your bandsaw each time you use it. Check for the following con- ditions and repair or replace when necessary.

1.Loose mounting bolts.

2.Worn switch.

3.Worn or damaged cords and plugs.

4.Damaged V-belt.

5.Any other condition that could hamper the safe operation of this machine.

Always perform any maintenance with the power off and the machine unplugged.

Table

The table and other non-painted surfaces on the Model G1019 should be protected against rust and pitting. Wiping the saw clean after every use ensures that moisture from wood dust isn’t allowed to trap moisture against bare metal sur- faces.

Some woodworkers recommend using automo- tive paste wax on exposed steel and cast iron surfaces. The wax provides a layer of protection, as well as reducing friction between lumber and the table, making cuts faster and smoother. Avoid waxes that contain silicone or other synthetic ingredients. These materials can find their way into lumber that’s being worked, and can make staining and finishing difficult. If you use paste wax, make sure that it’s 100% Carnauba wax.

Since all bearings are shielded and permanently lubricated, no maintenance is required on them. If after a period of time you notice a distinct noise or rumble coming from a shielded bearing, or the bearing journal is hot to the touch after use, it will be time to replace the shielded bearing assem- bly(s). Please contact our Customer Service num- ber to order replacement bearings or to make arrangements to send your bandsaw back for ser- vice.

V-Belt

Inspect V-belt regularly for tension and wear. Replace when necessary. Check pulleys to ensure that they are properly aligned and secure- ly tightened. See “Motor Assembly” instructions for proper tension and pulley alignment proce- dures.

Disconnect power to the machine when perform- ing any maintenance or assembly. Failure to do this may result in serious personal injury.

-32-

G1019 14'' Bandsaw

Image 34
Contents Bandsaw Page Table Of Contents Safety Safety Instructions For Power ToolsAMP Rating Additional Safety Instructions For Bandsaws Circuit Requirements 110V Operation 220V OperationExtension Cords Grounding General Information CommentaryUnpacking Piece InventoryClean up Site ConsiderationsAssembly StandCross Braces Right Angle Brace Switch Connecting switch to motor G1019 14 BandsawBandsaw To Stand Belt Aligning pulleys with plumb bob G1019 14 BandsawStand Guards Guard case in placeStar knobs Dust Port FenceBlades Fence in positionAdjustments Location Of ControlsBlade Tension Location of blade controlsBlade Tracking Blade GuidesTable Adjustments Support BearingsPage Fence Adjustment Blade Lead Test Run Operations GeneralBlade Information Changing BladesRipping Side and front views of a standard Bandsaw bladeStacked Cuts Cutting Curves Minimum circle radius vs. blade size G1019 14 BandsawCircle Cut Attachment Resawing Maintenance GeneralBearingsClosure Wiring Diagram Machine Data Sheet Troubleshooting Symptom Possible Cause Corrective ActionG1019 14 Bandsaw G1019 14 Bandsaw G1019 14 Bandsaw 01 P1019001A Upper Frame ARM Motor Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC