SECTION 2: CIRCUIT REQUIREMENTS
110V Operation
The Model G1022SM, Z and ZF motors are prewired to operate at 110V. See Figure 5 for a typical 110V installation.
G1022SM and G1022Z:
Under normal 110V use, the Models G1022SM and Z motors draw approximately 16 amps. We recommend a 20 amp circuit breaker or a 20 amp
G1022ZF:
Under normal 110V use, the Model G1022ZF motor draws approximately 17 amps. We recom- mend a 20 amp circuit breaker or a 20 amp slow- blow fuse.
The circuit you use should be dedicated, (i.e., the machine should provide the only draw from that circuit). If frequent circuit failures occur when using this machine, contact our Service Department or your local electrical contractor.
Because of the high amperage draw of the Model G1022 Series when wired for 110V, standard household circuit wiring may not be of a large enough gauge. A qualified electrician may need to install a new circuit with wires capable of handling a 20 amperage draw. Do not attempt to modify an existing circuit by replacing the circuit breaker with one rated for a higher amperage.
Figure 5. Typical 110V 3-prong plug and outlet.
G1022 Series Contractor Saws |