Grizzly instruction manual 220V Operation, G1022ZFX and G1022PRO

Page 11

220V Operation

G1022ZFX and G1022PRO:

The motors supplied with the Models G1022ZFX and G1022PRO are prewired to operate at 220V.

The Models G1022ZFX and G1022PRO are not supplied with a plug; therefore, a suitable 220V plug must be wired in. When operating at 220V, we recommend using a NEMA-style 6-15 plug and outlet as shown in Figure 6A. You may also Òhard-wireÓ the machine directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring requirements.

Under normal use, the motor draws approximate- ly 13 amps at 220V. We recommend a 15 amp cir- cuit breaker for 220V operation. This should be satisfactory for normal use while providing enough protection against circuit damage caused by power surges. Always check to see if your cur- rent wires are capable of handling a 15 amp load. If you are unsure, consult the advice of a qualified electrician. Do not attempt to modify an existing circuit by replacing the circuit breaker with one rated for a higher amperage.

Figure 6A. Typical 220V 3-prong plug and outlet.

G1022 Series Contractor Saws

-9-

Image 11
Contents Table SAW Page Table Of Contents Safety Instructions For Power Tools SafetyAMP Rating Additional Safety Instructions For Table Saws Zero Clearance Table Inserts Push Sticks Featherboards Push PaddlesCommon Definitions, Terms and Phrases G1022ZF Circuit Requirements110V Operation G1022SM and G1022ZG1022ZFX and G1022PRO 220V OperationGrounding Extension Cords Commentary IntroductionG1022 Series Contractor Saws Piece Inventory UnpackingHardware Contents Bolt Hardware Recognition ChartSite Considerations Clean UpStand Assembly AssemblyBeginning Assembly All Models G1022ZF and ZFXAttaching pulley guard bracket HandwheelsMotorPage G1022ZF, G1022ZFX and G1022PRO WiringFence Rails Extension WingsBlade FenceBlade Guard Adjusting blade guardPage Table Insert Adjusting table insert height G1022 Series Contractor SawsG1022SM Fence AdjustmentsAttaching a sacrificial fence G1022 Series Contractor Saws G1022Z Fence Adjust measurement pointerAdjust measurement pointer G1022 Series Contractor Saws Blade Parallelism Table/trunnion assembly¡ blade parallelism measurement 90 Stops Next step for all models Worm GearMiter Gauge Initial Step, Model G1022ZF and ZFXTest Run OperationsPre-Run Check Ripping blade Blade SelectionVarious saw tooth cutting profiles CrosscuttingCross-cut operation RippingOptional dado blade system Dado OperationsSacrificial fence G1022 Series Contractor Saws Rabbet OperationsRabbet cutting G1022 Series Contractor Saws Tables MaintenanceGeneral LubricationG1022SM and Z Wiring Diagram G1022ZF, ZFX and PRO Wiring Diagram Closure Machine Data Sheet G1022SM G1022SM G1022SM G1022SM Parts List PRP02M Grizzly Model G1022Z Table SAW G1022Z G1022Z G1022Z G1022Z Parts List Pulley Guard Bracket Grizzly Model G1022ZF/ZFX/PRO Table SAW G1022ZF/ZFX/PRO G1022ZF/ZFX/PRO G1022ZF/ZFX/PRO G1022ZF/ZFX/PRO Parts List Switch L-BRACKET Symptom Possible Cause Corrective Action Troubleshooting GuidePush Stick Warranty Card Warranty and Returns Grizzly INDUSTRIAL, INC. P.O. BOX 2069 BELLINGHAM, WA