SECTION 3: CIRCUIT REQUIREMENTS
110V Operation |
| 220V Operation |
|
|
|
|
|
|
The Model G0555 motor is prewired to operate at 110V, and includes a plug (similar to the illustra- tion in Figure 1) that has a ground prong and two current carrying prongs. The plug should only be placed into a grounded outlet box similar to the one illustrated in Figure 1. Make sure the outlet that you plug into is properly installed and grounded in accordance with all local codes and ordinances.
Figure 1. Typical 110V 3-prong plug and outlet.
Under normal 110V use, the motor draws approx- imately 10 amps. We recommend a 15 amp cir- cuit breaker or a 15 amp slow-blow fuse.
We also recommend that the circuit you use should be dedicated, (i.e., the G0555 should pro- vide the only draw from that circuit). If frequent circuit failures occur when using the bandsaw, contact our Service Department or your local electrical contractor.
The Model G0555 motor can be wired to single- phase 220V. Under normal use, the motor draws approximately 5 amps at 220V. We recommend a 10 amp circuit breaker for 220V operation. This should be satisfactory for normal use while pro- viding enough protection for the circuits. Also, be sure the wires in your circuit are rated for at least 10 amp service.
This machine does not come supplied with a 220V plug, therefore a suitable 220V plug must be wired in. When operating at 220V, we recom- mend using a NEMA-style 6-15 plug and outlet. See Figure 1A. You may also Òhard-wireÓ the machine directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring requirements.
Figure 1A. NEMA 6-15 220V plug and outlet.
G0555 14" Ultimate Bandsaw |