Troubleshooting
Trouble | Possible cause | Suggested remedy | |
|
|
| |
Fires two nails at time. | The head of the nail is too small | Check nail size. | |
| (Head size should be 2.8mm - 3.3mm). |
| |
|
|
| |
| 18 gauge nails have been fitted. | Purchase correct size nails from your | |
|
| local Air Tool supplier. | |
|
|
| |
Nailer skips when driving | Dirt in the nose piece. | Drive channel needs to be cleaned. | |
brad nails. |
|
| |
Dirt or damage prevent nails or pusher | Magazine needs to be cleaned. | ||
| |||
| from moving freely in magazine. |
| |
|
|
| |
| Inadequate air flow to nailer. | The fittings, hose or air compressors | |
|
| needs to be checked. | |
|
|
| |
Air leaking near the top of | Loose screws. | Tighten screws. | |
the tool or in trigger area. | Worn or damaged |
| |
|
|
| |
Nailer runs slow or has | Nailer not lubricated sufficiently. | Nailer needs to be lubricated. | |
loss of power. |
|
| |
Exhaust port in the cap has been blocked. | Damaged internal parts needs to be | ||
| |||
|
| replaced by an authorized service centre. | |
|
|
| |
Air leaking near the bottom | Loose screws. | Tighten screws. | |
of the tool. | Worn or damaged |
| |
|
|
| |
Tool jams frequently. | Incorrect fasteners. | Verify approved fasteners of correct size. | |
| Damaged fasteners. | Replace with undamaged fasteners. | |
|
|
| |
| Magazine is dirty. | Clean magazine. | |
|
|
| |
| Magazine or nose screw loose. | Tighten screws. | |
|
|
|
WARNING: Disconnect tool from air supply before performing any cleaning and maintenance procedures.
15