Delta DLKC6580V2-1 How to Use Your Unit, Before Starting Break-in Procedure, How to Stop

Page 14
Pressure Release Valve

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve: When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.

Check Valve

Pressure Release Valve: The pressure release valve, located on the side of the pressure switch, is designed to automatically release compressed air

from the compressor head and the outlet tube when the air compressor reaches “cut-out” pressure or is

shut off. The pressure release valve allows the motor

to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches “cut-out” pressure.

Air Intake Filter (not shown) This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See “Maintenance”.

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the “OFF” position.

2.Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all contacts move freely and are not obstructed.

3.Open the globe valve fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period. NOTE: The shut-off valve is not supplied with this unit. You must purchase the shut-off valve separately.

4.Move the On/Auto/Off lever to “ON/AUTO” position. The compressor will start.

5.Run the compressor for 20 minutes. Make sure the globe valve is open and there is minimal air pressure build-up in tank.

D26161

14-ENG

Image 14
Contents Instructio N M Anual Safety Guidelines Definitions Hazard Attachments & Accessories Hazard What can Happen HOW to Prevent IT Fire, Inhalation, Damage to Vehicle Surfaces Glossary SpecificationsAccessories Duty CycleUnpacking AssemblyTools Required for Assembly To Add Oil To PumpAnchoring of the Air Compressor InstallationLocation of the Air Compressor Wiring Instructions Air Distribution SystemTypical Compressed AIR Distribution System Operation Know Your Air Compressor Description of OperationHow to Stop How to Use Your UnitBefore Starting Break-in Procedure How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve Checking To Drain TankOil ChangingAdjusting Belt Tension Air Filter Inspection and ReplacementBelt Replacement Inspect Air Lines and Fittings for Leaks Motor Pulley/Flywheel AlignmentAir Compressor Pump Intake and Exhaust Valves Air compressor Head Bolts TorquingService and Adjustments To Replace or Clean Check ValveMotor Additional ServiceStorage Troubleshooting Problem Cause CorrectionPressure reading Minal box area 25-ENG D26161 AIR Compressor Diagram Parts List KEY Part Number DescriptionPump Diagram Not Shown Limited Warranty

DLKC6580V2-1 specifications

The Delta DLKC6580V2-1 is an advanced industrial AC servo drive designed to deliver exceptional performance and efficiency in a wide range of automation applications. This servo drive is engineered to enhance system responsiveness while ensuring precise motion control, making it an ideal choice for industries such as manufacturing, packaging, and robotics.

One of the standout features of the DLKC6580V2-1 is its high-speed communication capabilities. The drive supports various communication protocols including EtherCAT, CANopen, and Modbus RTU, ensuring seamless integration into existing systems. This flexibility allows users to connect multiple drives in a network, facilitating coordinated motion control and optimizing the performance of complex machinery.

The DLKC6580V2-1 boasts a powerful control algorithm that provides excellent torque performance and dynamic response. The drive utilizes advanced PWM (Pulse Width Modulation) technology, allowing for smooth operation across a broad range of speeds. This results in minimizing vibrations and improving the overall lifespan of connected servo motors.

In terms of ease of use, the DLKC6580V2-1 features an intuitive user interface with built-in diagnostics and monitoring capabilities. This user-friendly design allows operators to configure parameters swiftly, monitor real-time performance, and troubleshoot any issues effectively. Additionally, it supports maintenance-free operation, significantly reducing downtime and operational costs.

Safety is a priority with the DLKC6580V2-1, which includes multiple safety features like over-voltage, over-current, and temperature protection. The drive is also compliant with international safety standards, ensuring it can be deployed in various environments without compromising personnel safety.

Moreover, the DLKC6580V2-1 is designed to operate efficiently across a wide range of temperatures, making it suitable for different working conditions. Its robust construction ensures reliability and durability, which is crucial for demanding industrial applications.

In conclusion, the Delta DLKC6580V2-1 AC servo drive is a high-performance solution that combines advanced control technology, versatile communication options, and user-friendly features. Its robust safety measures and adaptability to varying operational conditions make it an essential component for enhancing automation in modern industrial setups. Whether for precision machining or complex automation processes, the DLKC6580V2-1 stands as a reliable choice for engineers and manufacturers aiming to optimize their production capabilities.