Emerson SZO44, SZV44, SZV32, SZO56 manual 110, 130 140

Page 36

Dual-Compressor Module

Technical Support and Service

 

 

Compressor Module

Horsepower Selection Chart

Module Model Number: SZO56C1A-EDE-240

Configuration

Suction

Max Flow/HP as a function of discharge pressure at maximum flow

 

Press

 

 

 

rate

(Note 1)

 

 

 

 

 

(PSIG)

 

 

 

 

 

 

 

 

 

 

 

 

MCFD)

70

80

90

 

100

110

120

130

140

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One Module Package

-7.5

MCFD

43

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

19

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

MCFD

97

96

96

 

95

94

94

94

93

93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

19

21

23

 

25

26

27

29

30

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

MCFD

131

130

130

 

129

128

128

127

127

126

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

21

23

24

 

26

27

29

30

31

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

MCFD

165

164

164

 

163

163

162

161

160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

23

24

26

 

27

28

30

31

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

MCFD

 

198

198

 

197

197

196

195

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

25

27

 

28

30

31

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

MCFD

 

232

232

 

232

231

230

229

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

27

28

 

30

31

31

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

MCFD

 

 

 

 

265

264

264

264

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

 

 

 

31

31

32

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two Module Package

-7.5

MCFD

86

84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

37

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

MCFD

194

193

191

 

190

188

188

188

187

185

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

39

43

46

 

49

52

55

58

60

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

MCFD

262

261

259

 

258

257

256

255

253

252

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

42

45

49

 

52

54

57

60

63

66

 

10

MCFD

329

329

328

 

327

325

323

321

320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

45

48

51

 

54

57

60

63

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

MCFD

 

396

396

 

395

394

392

390

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

51

54

 

57

59

61

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

MCFD

 

464

465

 

463

463

460

458

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

54

56

 

59

62

63

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

MCFD

 

 

 

 

530

529

528

527

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

 

 

 

 

62

63

64

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.

2.Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig

3.Performance data to be used as an estimation guide only and is subject to change without notice

30

2006SSD-75 R4 (10/10)

Image 36
Contents Copeland Scroll Compressor Module Page Table of Contents Appendix A Material Data Safety Sheet Figures Compressor Module Nomenclature Important Safety Information Safety Alert Symbol Safety Symbols Used in This ManualCompressor Module IntroductionOil coolers with fans Compressor Compressor PackageInlet gas scrubber for liquid removal Installation Guidelines General Installation GuidelinesInlet and Discharge Pressures Required Component-Inlet Gas ScrubberAmbient Temperature Range Barg SettingModule Weight Lbs. kg Installation Clearance and Dimensions Compressor Module Dimensions, in. mmProcess and Instrumentation Diagrams P&IDs Code DescriptionSwitches SwitchStatusElectrical Controls General ConsiderationsOil Cooler Fan Control Brushless DC FanTemperature Control SZO44Variable Speed DriveTypical Compressor Module power supply requirements Compressor Power data based on 480VAC Variable SpeedElectrical Requirements Wiring Control Circuit TerminationsPre-Startup Checklist Post-Startup ChecklistInitial Startup Compressor Module OperationCheck for These Conditions Under Normal Operation Routine Maintenance MaintenanceMaintenance summary Maintenance Tools Maintenance ToolsChecking the Oil Level Oil Capacity and TypeOil Level Guidelines Minimum Speed Oil Level Guidelines Maximum SpeedAdding and Removing Oil Topping Off the Oil LevelAdding Oil Changing the Oil Draining OilReplacing Oil Cleaning the Inlet Screen Servicing the Scavenge Line OrificeChanging the Second-Stage Separator Element Changing the Oil Filter ElementTroubleshooting Guide TroubleshootingMotor Winding Resistance Motor winding resistancePlatform Symptoms Diagnosis Platform troubleshooting guidelinesSpecifications Compressor Module Specifications Dual-Compressor Module Technical Support and Service Configuration Suction Max Flow/HP as a function of discharge110 130 140Flow rate 110 120150 180Appendix A - Material Data Safety Sheet SupplierEmergency Number 989 Product Name and Information Components and Hazard StatementSpill or Leak Procedures Fire and Explosion HazardsReactivity Data Health Hazard DataPage Page EmersonClimate.com
Related manuals
Manual 44 pages 48.85 Kb