1.3 ORDERING INFORMATION

The Model 399VP pH/ORP Sensor is available with custom glass electrodes housed in a molded Tefzel body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation. The sensor includes a general purpose hemi bulb pH electrode (flat bulb optional) or a platinum ORP electrode and a double or triple junction gel filled reference electrode. Automatic temperature compensation is standard with the Model 399VP pH, but is not required on the Model 399VP ORP (except when used with the Model 1054A ORP Microprocessor Analyzer). The 399VP is offered with the Variopol (VP) connector and uses a mating VP cable (purchased separately). A remote preamplifier must be used with this sensor.

MODEL

 

399VP

pH/ORP SENSOR

 

 

Code

399VP pH (GPLR hemi bulb) Preamplifier/Cable (Required Selection)

02

3K ohm TC (Models 1181, 1050, and 1003)

09

Pt100 TC (Models 54pH, 1054A/B, 1055, 2054, 2081 pH, 81, 3081, and 4081)

 

 

Code

Glass Type (optional - choose one; not valid with special application codes)

11

High pH

15HF Resistant

71GPLR Flat bulb

Code

Special Applications - valid with only standard hemi glass (optional - choose one)

301

Low ionic strength water

 

 

302

Heavy reference poisoning ions (triple reference junction)

303

High temperature spikes or Low temperature storage

33

ORP sensor

 

 

 

 

PN

Mating VP Connector Cable (required for all new installations)

23645-06

15 ft cable with mating VP connector, prepped with BNC on analyzer end

 

 

23645-07

15 ft cable with mating VP connector, prepped without BNC on analyzer end

 

 

FOR FIRST TIME 399VP* INSTALLATIONS, WE RECOMMEND USING THE FOLLOWING GUIDE:

1. Mounting Accessories (optional)

Choose one: PN

23242-02, Mounting adapter kit, 1/2 in. MNPT process connection, 1 in. x 3/4 in. sensor adapter

PN

915240-03, PVC flow through tee, 3/4 in. NPT process connection

PN

915240-04, PVC flow through tee, 1 in. NPT process connection

PN

915240-05, PVC flow through tee, 1-1/2 in. NPT process connection

PN

24091-00, Acrylic low flow cell

PN

2002011, 1-1/2 in. CPVC tee with 1-in. FNPT connection

PN

9330022, Pipe mount union, 1 in. x 1 in. CPVC (for sensor to analyzer distance extension)

PN

11275-01, Sensor handrail assembly

PN 1000857, Handrail mounting kit (pipe and sensor coupling supplied by others)

2. Junction Boxes (optional)

Remote Junction Boxes (to extend sensor to analyzer distances)

Choose one: PN 23555-00, includes preamplifier for Models 54, 81, 3081, 4081; NEMA 4X

PN 22719-02, Weatherproof junction box for cable extension

PN 23309-03, use with 1181 and 1050 compatible preamplifier

PN 23309-04, use with 1054/A/B, 2054, 2081 compatible preamplifier

3. Preamplifiers (used to amplify signal when mounting sensor further than 15 ft from the analyzer)

Choose one: PN 22698-02, Plug in preamplifier, 1181/1050 compatible (use with junction box PN 23309-03)

PN 22698-03, Plug in preamplifier, 1054/1054A/1054B/2054/ 2081 compatible (use with junction box PN 23309-04)

4. Extension cables (used with remote junction boxes)

Choose one: PN 23646-01, 11 conductor cable, shielded, prepped

PN 9200000, 4 conductor cable, shielded, unprepped

5. Other optional accessories

Choose one: PN

12707-00, Jet spray cleaner

PN

2001492, Stainless steel tag, specify marking (formerly Code -11)

PN

9210012, Buffer solution, 16 oz, 4.01 pH

PN

9210013, Buffer solution, 16 oz, 6.86 pH

PN

9210014, Buffer solution, 16 oz, 9.18 pH

PN

22698-00, Plug-in preamplifier, 1003 compatible

 

 

 

* Also requires mating VP cable — see 399VP Ordering Information above.

2

Image 6
Contents Combination pH/ORP Sensor Hazardous Area Installation Essential InstructionsTable of Contents Model 399VP pH/ORP SensorList of Figures List of TablesPhysical Specifications Section Description and SpecificationsFeatures and Applications Graph A. Pressure/Temperature Limitations For Model 399VPMounting Accessories optional Ordering InformationMounting Section InstallationUnpacking and Inspection Mounting GuidelinesSensor Dimensions FLOW-THROUGH Installations Model 399VP Shown in Various Flow Through InstallationsInsertion Installations Model 399VP Shown in LOW Flow Cell Assembly PNSubmersion Installations Adapter PNSensor Shown in Handrail Mounting Assembly PN JET Spray Cleaner PN Used with Model 399VP Section Wiring SCLWire and Connector Pin Functions Model 54 Wiring Model 81 Wiring through Remote Junction Box 13. Model 1054 Wiring 17. Model SCL-P/Q Wiring 41055107 41055108 23. Preparation of Extension Cable PN Sensor Preparation Recommended two-point buffer calibration procedureSection START-UP and Calibration Recommended pH Sensor Standardization268 264 260 Section Maintenance Automatic Temperature CompensatorGeneral PH Electrode Cleaning ORP Platinum Electrode CheckSection Troubleshooting Problem Probable Cause RemedySection Return of Material GeneralReturn of Materials Request Sensor or Circuit Board onlyEUROPE, Middle EAST, and Africa Americas HeadquartersASIA-PACIFIC Additional Sales OfficesWarranty Specifications subject to change without notice