IMPORTANT SAFETY
INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND INSTRUCTIONS.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save these instructions - This operator’s manual contains important safety and operating instructions for the MILWAUKEE Laser Distance Meter. Before using the Laser Distance Meter, read this operator’s manual and all labels on the Laser Distance Meter.
parts. This will ensure that the safety of the tool is maintained.
• Do not disassemble. Incorrect reas- |
sembly may result in the risk of electric |
shock or fire. If it is damaged, take it to |
a MILWAUKEE service facility. |
• Store in a cool, dry place. Do not |
store where temperatures may exceed |
158°F (70°C) such as in direct sunlight, |
a vehicle or metal building during the |
summer. |
dust free glass, Styrofoam or similar
TECHNICAL
SPECIFICATIONS
Range | 0.16' to 197' * |
| (0.05 m to 60 m) * |
LASER SAFETY
•Laser light - Do not stare into beam or view directly with optical instruments. Do not point laser light at others. Laser light can cause eye damage.
•Avoid exposure to laser radiation. Laser may emit hazardous radiation.
•Do not point laser at reflective surfac- es. Unpredictable results may occur.
WORK AREA SAFETY
•Keep children and bystanders away while operating Laser Distance Meter. Store idle Laser Distance Meter out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate it.
•Avoid dangerous environments. Do not use in rain, snow, damp or wet locations. Do not use in the presence of explosive atmospheres (gaseous fumes, dust or flammable materials) because sparks may be generated when inserting or removing batteries, possibly causing fire.
PERSONAL SAFETY
•Stay alert, watch what you are do- ing and use common sense when operating Laser Distance Meter. Do not use while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention may result in serious personal injury.
•Do not overreach. Keep proper foot- ing and balance at all times. This enables better control in unexpected situations.
BATTERY USE AND CARE
•This tool is designed to be powered by
•Do not leave batteries within the reach of children.
•Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
•Do not mix rechargeable and non- rechargeable batteries.
•Install batteries according to polarity (+ /
•Properly dispose of used batteries immediately.
•Do not incinerate or dismantle bat- teries.
•Under abusive conditions, liquid may be ejected from the battery, avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
SERVICE
•Have your Laser Distance Meter serviced by a qualified repair person
2using only identical replacement
HAZARDS OF USE
•Do not remove or deface labels. Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE service facility for a free replacement.
•Watch out for erroneous distance measurements if the meter is defec- tive or if it has been dropped or has been misused or modified. Carry out periodic test measurements.Particularly after the meter has been subject to ab- normal use, and before, during and after important measurements. Make sure the optic is kept clean and that there is no mechanical damage to the bumpers.
•In using the meter for distance mea- surements or for positioning moving objects (e.g. cranes, building equip- ment, platforms, etc.) unforeseen events may cause erroneous mea- surements. Only use this product as a measuring sensor, not as a control device. Your system must be config- ured and operated in such a way, that in case of an erroneous measurement, malfunction of the device or power failure due to installed safety measures (e.g. safety limit switch), it is assured that no damage will occur.
•Target Surfaces- Measuring errors can occur when measuring toward colourless liquids (e.g. water) or 3
Measuring accuracy | typically 0.059" * |
| (1.5 mm) * |
Smallest unit displayed | 1/16" (1 mm) |
Laser type | Class 2 |
Max power | < 1 mW |
Laser wavelength | 632 nm |
Protection level | IP 54, |
| |
Automatic power OFF- | after 1 min |
Laser |
|
Automatic power OFF- | after 3 min |
Display |
|
Display Backlight | yes |
Fold out end bracket | yes |
Battery usage | 2 AAA |
Battery life | up to 5000 |
| measurements |
Dimension | 4.5" x 2" x 1.1" |
| (114 x 51 x 27 |
| mm) |
Weight | 4.2 oz (120 g) |
Storage | |
Temperature range | (25°C to 70°C) |
Operation | 32°F to 104°F |
Temperature range | (0°C to 40°C) |
*In difficult conditions, with intense sunshine, a poorly reflecting target surface or at high temperatures, the deviation over distances about 32' (10 m) can increase by +0.006" (+0.15 mm) per meter.