Sterling A0544325 Returns, SMC050A Process Pump Curves, SMC100A Process Pump Curves

Page 10

1-9 Returns

Important!

Do not return any damaged or incorrect items until you receive shipping instructions from STERLCO.

Figure 1

SMC050A Process Pump Curves

SMC050A - PROCESS PUMPS SELECTIONS

TOTAL HEAD

 

 

60 HERTZ PUMP CURVE

MTRS PSI

FEET

 

 

49

69

160

 

 

 

37

52

120

BZ050A

BZ050B

BZ050C

 

 

 

24

35

80

 

 

 

12

18

40

 

 

 

U. S. GALLONS

0.4

0.8

1.2

1.6

2.0

2.4

2.8

3.2

3.6

4.0

4.4

4.8

PER MINUTE

 

 

 

 

 

 

 

 

 

 

 

 

LITRES

1.5

3.0

4.5

6.1

7.6

9.1

10.6

12.1

13.6

15.1

16.7

18.2

PER MINUTE

 

 

 

 

 

 

 

 

 

 

 

 

CURVES REPRESENT PUMP DISCHARGE ADJUSTED FOR INTERNAL BY-PASS

Do not extrapolate pump curves.

Figure 2

SMC100A Process Pump Curves

 

SMC100A- PROCESS PUMPS SELECTIONS

TOTAL HEAD

60 HERTZ PUMP CURVE

MTRS PSI FEET

49

69

160

 

37

52

120

BZ100C

BZ100B

 

 

 

24

35

80

BZ100A

12

18

40

 

U. S. GALLONS 1.6

2.0

2.4

2.8

3.2

3.6

4.0

4.4

4.8

5.2

5.6

6.0

6.4

PER MINUTE

 

 

 

 

 

 

 

 

 

 

 

 

 

LITRES

6.1

7.6

9.1

10.6

12.1

13.6

15.1

16.7

18.2

19.7

21.2

22.8

24.2

PER MINUTE

CURVES REPRESENT PUMP DISCHARGE ADJUSTED FOR INTERNAL BY-PASS

Do not extrapolate pump curves.

Page 10

 

SMC Series Chillers

 

 

Image 10
Contents SMC-050 to SMC-150 Series SMC Series Chillers Safety Considerations Table of Contents Table of Contents Charts and Figures Necessary Documents General InformationIntroduction Models CoveredAvailable Options Uncrating Your New ChillerIf the Shipment is Not Complete Event of Shipping DamagesIf the Shipment is Incorrect SMC050A Process Pump Curves ReturnsSMC100A Process Pump Curves SMC150A Process Pump Curves SMC Series Chiller Specifications SMC-150 25,400 16,000 12A 345Electrical Connections Chiller InstallationProcess Water Connections SMC Condenser Air Supply Water ReservoirEthylene Glycol Curve Overhead Process Considerations Overhead PipingChilled Water Circuit Sequence of OperationRefrigeration Circuit Low Pressure Cutout High Pressure CutoutRemote Start/Stop Interlock SMC Component Identification Piping Schematic 1 Pump with Reservoir End of unit pipingPiping Schematic 1 Pump without Reservoir Piping Schematic No Pump, No Reservoir SMC Pre-Startup Checklist SMC Startup ChecklistSMC Water Circuit Pressure Drop Table Setting the Alarm Value Setting the Process Water TemperatureMicroprocessor Control SMC Control SP ALSwitches Indicator LightsOptional Graphic Panel SMC Series Optional Graphic PanelLubrication Routine MaintenanceCondenser Maintenance Typical SMC SubpanelTypical SMC Wiring Schematic SMC Wiring Schematic for Chillers with No Pump or Reservoir SMC Series Chillers Troubleshooting Guide Problem Possible cause SolutionProblem Possible cause Solution SMC Spare Parts List DescriptionService Notes Service Notes Milwaukee, WI Sterling/Sterlco5200 West Clinton Avenue 414 Fax 414