Before Installing on a Rack

Before installing on a rack, be sure that the environment is within the recommended range:

Operating temperature range

+5 to +45 Deg. Centigrade

Operating humidity range

5 to 65 % RHL, non-condensing

Storage temperature range

-20 to +70 Deg. Centigrade

Storage humidity range

5 to 95% RHL, non-condensing

CAUTION!!

When installing on a 19" rack, avoid hazards by taking care that:

1It is located within the recommended environmental conditions, as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature.

2Once rack mounted, enough air will still flow around the machine.

3The machine is placed straight in the correct horizontal position.

4You do not overload the circuit(s). When connecting the machine to the supply circuit, overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring. Refer to the appropriate nameplate ratings for information. For example, for fuse replacement, see the value printed on the product label.

5The machine is earthed (grounded) in a reliable way and is connected only to an electricity socket with grounding. Pay particular attention to supply connections other than direct connections to the branch circuit (for example, the use of power strips), and that you use only the power cord that is supplied with the machine.

How to Rack Mount

To rack-mount the machine:

1Attach both ear brackets to the machine. To do so, remove the screws from each side of the machine (3 on each side), and replace those screws through the ear brackets.

2Place the ears of the machine against the rack rails, and insert the proper screws (not provided) through each of the four holes in the rack ears.

Note that:

￿In some models, the front panel may feature built-in rack ears

￿Detachable rack ears can be removed for desktop use

￿Always mount the machine in the rack before you attach any cables or connect the machine to the power

￿If you are using a Kramer rack adapter kit (for a machine that is not 19"), see the Rack Adapters user manual for installation instructions (you can download it at: http://www.kramerelectronics.com)

6

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Image 9
Contents Model Contents Tables FiguresIntroduction Getting StartedQuick Start Getting Started Your VA-2002 Multistandard Logo Generator OverviewVA-2002 Multistandard Logo Generator Front Panel VA-2002 Multistandard Logo Generator Features Before Installing on a Rack Installing the VA-2002 on a RackConnecting the VA-2002 Multistandard Logo Generator Connecting the VA-2002 Multistandard Logo Generator Click Install/Remove Software. The Welcome window appears Installing the VA-2002 SoftwareClick Next Start Menu window appears, as illustrates Installation Window VA-2002 Logo Finalizer and Upload Program Toolbar Buttons Using the VA-2002 Logo Finalizer and Upload ProgramHeight Logo Graphics Characteristics and LimitationsUnnamed VA-2000 Window Saving a Logo to a Floppy DiskSelecting a Bitmap File Solid Logo on the Center Right Side of the Screen Transparent Logo on the Center Right Side of the Screen Adding Transparency to a LogoSet Transparency Box Setting the Fade SpeedConfiguring the Remote Control Program Using the VA-2002 Remote Control ProgramCOM-Port Window Transferring a Logo via RS-232 Controlling the VA-2002 from the Remote Control ProgramLogo Info Window Before RS-232 Transfer Identification and Status Screens Operating via the VA-2002 Front PanelSEL Logo Accessing the Main MenuEditing a Logo from the Main Menu Deleting a Logo from the Main Menu Checking System Information from the Main Menu Includes the technical specifications Technical SpecificationsOnly the first purchase customer may enforce this warranty 2900-006017 REV