Altinex PE1005 manual IP Address, Configure the Device

Page 10

SPECIAL APPLICATION

6.Click on the “Search” button to check for new devices on the LAN.

NOTE: If you want to assign the IP manually, click “Assign IP”. This method will require the hardware address on the device and the assistance of your IT Administrator.

THE IP ADDRESS

7.Once the device is located, click on the device in the installer window and make note of the Internet address.

CONFIGURE THE DEVICE

8.The device may be configured using a web browser or using a Telnet session. This procedure uses the Telnet option. Click the “Telnet” button and do not change the default port number of “9999”.

9.When the command window appears, press ENTER when prompted to enter Setup Mode and then select the factory defaults.

10.Next, select “Channel 1 Configuration”.

11.View each line item as it appears. Press ENTER to leave the default value, or enter the new value and press ENTER.

NOTE: The “Port No.” in the configuration menu is the COM port for use with RS-232 communication software.

11.Select “Save and Exit” to keep changes and exit setup mode.

12.Close the DeviceInstaller, setup is complete. Use the port number assigned above to communicate with the PE-1005 over the LAN.

400-0384-003

9

Image 10
Contents PE1005 Table of Contents Precautions / Safety Warnings Technical Specifications About Your PE1005Diagram 1 Typical Setup Application DiagramsDescription of PE1005 Diagram 2 Internal View Pioneer Control CardLED1 Diagram 3 Card DetailsBattery SW1Diagram 4 25-PIN HD Details Diagram 5 Motion Detector DetailsUSB Setup Installing Your PE1005External Port Setup TCP/IP SetupConfigure the Device IP AddressOperation Description of CommandsFreset StatusWait VERTest RDIWRRLk=x RdrlWRRLx1x2x3x4 WrinWrls WRSRDS Clrls RdlsClrs SUBSetdate SettimeSetday RdtimeSET1ALRM2 Mode 2 Every Hour Alarm #1 CommandsSET1ALRM1 Mode 1 Every Minute RddateSET1ALRM5 Mode 5 Once a Week SET1ALRM3 Mode 3 Once a DaySET1ALRM4 Mode 4 Once a Month ALRM1=SUB10SET2ALRM2 Mode 2 Every Hour Alarm #2 CommandsSET2ALRM1 Mode 1 Every Minute ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM5 Mode 5 Once a Week SET2ALRM3 Mode 3 Once a DaySET2ALRM4 Mode 4 Once a Month ALRM2=SUB10Rdalrm AlrmonAlrmoff ALRMn=SUBkRdlm WrlmRDM ClrmModersi OutpdpmSendbs OutvcmSendrs Sendps58. MD1 MdonMdoff 59. MD0MD0=SUB10 MD1=SUB11 MdtypeRdmd RSIRSN Summary of CommandsSIDnCi Rddate Display date from clockSending Commands to Internal BUS Internal Command FormatPlasma Control with Internal BUS There is no Communication Troubleshooting GuidePioneer Plasma Commands Relays do not WorkInput Ports do not Respond Limited WARRANTY/RETURN PoliciesAltinex Policies Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.