Altinex PE1005 manual Wrlm, Rdm, Rdlm, Clrm

Page 22

SPECIAL APPLICATION

Hex characters can be added to the string by using the % sign in front of the hex number. Sending %0C will send the hex “0C”, or form feed character. The three characters making up the hex number cannot be separated and must be in the same string. Below are some common hex numbers:

%5B = ‘ [ ‘

%5D = ' ] '

%7B = ’ { ‘

%7D = ' } '

%3C = ' < '

%3E = ' > '

Example:

 

Program RS memory location 50 with the string “STANDBY_ON” by sending the command

[WRM50=STANDBY_ON;1]. Using the ‘1’ option, this will overwrite whatever information is currently in location 50 and save the command “STANDBY_ON”.

41.[WRLM]

This command assigns a label to a memory location. This label can help identify the contents or function of the data stored in the memory location. The label may be up to eight characters.

Command Format: [WRLMm=<xxxxxx>Ci]

m= Memory Location (m = # from 1 to 99) x = Label Name (8 characters max)

Ci = Unit ID (i = # from 1 to 99)

Example:

Add the label “STANDBY” to memory location

50 by sending the command [WRLM50=<STANDBY>].

42.[RDM]

This command displays the data for one or all memory locations. The data shows the memory location number, the memory label and then the contents of the memory location.

Command Format: [RDMmCi]

m = Memory Location (m = 1 to 99, * for all)

Ci = Unit ID (i = # from 1 to 99)

Example:

Read back the contents of all the memory locations by sending the command [RDM*]. The feedback will be in the following format:

MEM1/NONE/: ON

MEM2/NONE/: OFF

MEM99/NONE/Memory Empty

43.[RDLM]

This command displays the data for one or all memory location labels.

Command Format: [RDLMmCi]

m = Memory Location (m = 1 to 99, * for all)

Ci = Unit ID (i = # from 1 to 99)

Example:

Read back the contents of all the memory labels by sending the command [RDLM*]. The feedback will be in the following format:

MEM1:STOP

MEM2:PLAY

MEM99:NONE

44.[CLRM]

This command clears one or all RS-232 memory location. The memory for the subroutines is not affected.

Command Format: [CLRMmCi]

m = Memory Location (m = 1 to 99, * for all)

Ci = Unit ID (i = # from 1 to 99)

Example:

Clear the contents of all RS-232 memory locations by sending the command [CLRM*]. The PE1005 will respond with the following feedback:

ALL SUBS WILL BE CLEARED

PLEASE WAIT

400-0384-003

21

Image 22
Contents PE1005 Table of Contents Precautions / Safety Warnings Technical Specifications About Your PE1005Diagram 1 Typical Setup Application DiagramsDescription of PE1005 Diagram 2 Internal View Pioneer Control CardLED1 Diagram 3 Card DetailsBattery SW1Diagram 4 25-PIN HD Details Diagram 5 Motion Detector DetailsUSB Setup Installing Your PE1005External Port Setup TCP/IP SetupConfigure the Device IP AddressOperation Description of CommandsFreset StatusWait VERTest RDIWRRLk=x RdrlWRRLx1x2x3x4 WrinWrls WRSRDS Clrls RdlsClrs SUBSetdate SettimeSetday RdtimeSET1ALRM2 Mode 2 Every Hour Alarm #1 CommandsSET1ALRM1 Mode 1 Every Minute RddateSET1ALRM5 Mode 5 Once a Week SET1ALRM3 Mode 3 Once a DaySET1ALRM4 Mode 4 Once a Month ALRM1=SUB10SET2ALRM2 Mode 2 Every Hour Alarm #2 CommandsSET2ALRM1 Mode 1 Every Minute ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM5 Mode 5 Once a Week SET2ALRM3 Mode 3 Once a DaySET2ALRM4 Mode 4 Once a Month ALRM2=SUB10Rdalrm AlrmonAlrmoff ALRMn=SUBkRdlm WrlmRDM ClrmModersi OutpdpmSendbs OutvcmSendrs Sendps58. MD1 MdonMdoff 59. MD0MD0=SUB10 MD1=SUB11 MdtypeRdmd RSIRSN Summary of CommandsSIDnCi Rddate Display date from clockSending Commands to Internal BUS Internal Command FormatPlasma Control with Internal BUS There is no Communication Troubleshooting GuidePioneer Plasma Commands Relays do not WorkInput Ports do not Respond Limited WARRANTY/RETURN PoliciesAltinex Policies Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.