Altinex PE1005 manual Plasma Control with Internal BUS, Internal Command Format

Page 28

SPECIAL APPLICATION

46)

[MODERSI]

Set internal baud rate

 

47)

[RDRSI]

Read internal baud rate

 

48)

[OUTRSM]

Send

memory

data

via

 

 

external RS-232

 

 

49)

[OUTBSM]

Send

memory

data

via

 

 

internal RS-232

 

 

50)

[OUTPDPM]

Send

memory

data

to

 

 

plasma main card

 

 

51)

[OUTVCM]

Send

memory

data

to

 

 

plasma video card

 

52)

[SENDRS]

Send data via external bus

53)

[SENDBS]

Sends data via internal bus

54)

[SENDPS]

Send data to display card

55)

[SENDVS]

Send data to video card

 

56)

[MDON]

Enable motion detector

 

57)

[MDOFF]

Disable motion detector

 

58)

[MD1]

Set approaching sub

 

59)

[MD0]

Set departing sub

 

 

60)

[SETMD]

Set detector trigger value

61)

[SETTMD]

Set detector time delay

 

62)

[MDTYPE]

Set detector type

 

 

63)

[RDMD]

Read detector settings

 

64)

[RSI]

Reset card ID

 

 

65)

[SIDn]

Set ID of cards

 

 

66)

[SIDnCi]

Set ID of a single card

 

67)

[RSN]

Read ID number

 

 

7.4 PLASMA CONTROL WITH INTERNAL BUS

The PE1005 has the capability of sending commands directly to the plasma’s internal bus or to third-party video cards installed in the plasma. This allows the user to control settings on the display without having to use the menu buttons on the display or with the remote control.

As in the previous sections, commands are sent via standard RS-232 communication. Commands may be sent directly to the internal bus, or stored into RS memory locations and recalled from the memory location and sent to the bus. The commands for communicating with the internal bus are [OUTPDPM] and [SENDBS]. See the previous sections for details on these two commands, including restrictions on the number of characters that may be stored or sent in a single command.

7.4.1 INTERNAL COMMAND FORMAT

The internal commands for the PE1005 are in the following format and must contain the protocols indicated:

1.

Start of text. (STX)

%02

2.

Plasma ID (default)

%2A%2A

3.

Command ID

See Appendix A of the

 

 

Pioneer manual

 

 

mentioned earlier.

4.

End of text. (ETX)

%03

7.4.2 SENDING COMMANDS TO INTERNAL BUS

The default baud rate for the PE1005 is 9600 baud. Prior to sending any commands, verify both the plasma and PE1005 are set to 9600 baud.

In order to change setting values, the plasma must be in adjustment mode. The plasma may be placed into adjustment mode by sending the command AJY.

The following examples demonstrate communication with the plasma through the internal bus using both stored commands and direct commands. All commands may be sent to the plasma using either method.

Example 1: Adjustment Mode

Place the plasma into adjustment mode by sending the following command directly to the internal bus:

[SENDBS<%02%2A%2AAJY%03>]

400-0384-003

27

Image 28
Contents PE1005 Table of Contents Precautions / Safety Warnings Technical Specifications About Your PE1005Diagram 1 Typical Setup Application DiagramsDescription of PE1005 Diagram 2 Internal View Pioneer Control CardDiagram 3 Card Details BatteryLED1 SW1Diagram 4 25-PIN HD Details Diagram 5 Motion Detector DetailsInstalling Your PE1005 External Port SetupUSB Setup TCP/IP SetupConfigure the Device IP AddressDescription of Commands FresetOperation StatusVER TestWait RDIRdrl WRRLx1x2x3x4WRRLk=x WrinWrls WRSRDS Rdls ClrsClrls SUBSettime SetdaySetdate RdtimeAlarm #1 Commands SET1ALRM1 Mode 1 Every MinuteSET1ALRM2 Mode 2 Every Hour RddateSET1ALRM3 Mode 3 Once a Day SET1ALRM4 Mode 4 Once a MonthSET1ALRM5 Mode 5 Once a Week ALRM1=SUB10Alarm #2 Commands SET2ALRM1 Mode 1 Every MinuteSET2ALRM2 Mode 2 Every Hour ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM3 Mode 3 Once a Day SET2ALRM4 Mode 4 Once a MonthSET2ALRM5 Mode 5 Once a Week ALRM2=SUB10Alrmon AlrmoffRdalrm ALRMn=SUBkWrlm RDMRdlm ClrmModersi OutpdpmOutvcm SendrsSendbs SendpsMdon Mdoff58. MD1 59. MD0Mdtype RdmdMD0=SUB10 MD1=SUB11 RSISummary of Commands SIDnCiRSN Rddate Display date from clockSending Commands to Internal BUS Internal Command FormatPlasma Control with Internal BUS Troubleshooting Guide Pioneer Plasma CommandsThere is no Communication Relays do not WorkLimited WARRANTY/RETURN Policies Altinex PoliciesInput Ports do not Respond Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.