Altinex manual Installing Your PE1005, External Port Setup, USB Setup, TCP/IP Setup

Page 9

SPECIAL APPLICATION

INSTALLING YOUR PE1005

6

Step 1. Turn off the power to the plasma display.

Step 2. Use ESD safety precautions and always wear a ground strap when handling the PE1005.

Step 3. Prepare the card if necessary using the application diagrams on page 7.

Step 4. Remove the card or cover currently installed at the bottom of the display.

Step 5. Carefully insert the PE1005. Use the thumbscrews to tighten the card securely into place.

Step 6. If using RS-232 control, connect the RS-232 communication port of the PC or other control device to the PE1005 through the Digital I/O port using a 25-pin HD connector and cable. See DIAGRAM 4: 25-PIN HD DETAILS for pinout information.

NOTE: RS-232 operation: Use AVSnap or other RS-232 communication software.

Step 7. Turn on power to the plasma display.

EXTERNAL PORT SETUP

In addition to the controls available through the 25-pin HD connector, the PE1005 may also be controlled through its USB or LAN ports. The drivers required for configuring these ports are

available on the ALTINEX website, www.altinex.com. If there are any questions or difficulties installing these drivers, please call ALTINEX at (714)-990-2300.

USB SETUP

1.Download the TUSB3410 driver from the ALTINEX website, www.altinex.com.

2.Do not connect the PE1005 to the USB port on the computer until after the drivers are installed.

3.Check for a “readme” file that may contain special installation instructions. If there is a “readme” file, print and read the contents prior to running the application.

4.Launch the application.

5.Follow the instructions provided by the Installation Wizard.

6.Connect the PE1005 to the computer’s USB port. The unit should be operational. If not, it may be necessary to reboot the computer.

Note: In some cases, it is necessary to use the Device Manager in Windows® and direct Windows® to install the drivers located at the path displayed during the installation procedure in Step 5 above.

TCP/IP SETUP

1.Download the “DeviceInstaller” for the XPort device from the ALTINEX website, www.altinex.com.

The “DeviceInstaller” is a configuration utility for the Ethernet to serial controller. This

software requires Windows .NET Framework to be installed on the computer. The .NET Framework should be revision 1.1 or later.

2.Run the “setup.exe” file from the downloaded files.

This will install the DeviceInstaller on your system. Make note of where the software is installed on your computer.

3.Connect the XPort device to the LAN using standard CAT-5 cable.

4.The device must be installed in a system and have power turned on in order to proceed.

5.Launch the Lantronix/DeviceInstaller from the START menu or from the directory

noted earlier. This will allow the configuration of the XPort device.

400-0384-003

8

Image 9
Contents PE1005 Table of Contents Precautions / Safety Warnings About Your PE1005 Technical SpecificationsApplication Diagrams Diagram 1 Typical SetupDescription of PE1005 Pioneer Control Card Diagram 2 Internal ViewBattery Diagram 3 Card DetailsLED1 SW1Diagram 5 Motion Detector Details Diagram 4 25-PIN HD DetailsExternal Port Setup Installing Your PE1005USB Setup TCP/IP SetupIP Address Configure the DeviceFreset Description of CommandsOperation StatusTest VERWait RDIWRRLx1x2x3x4 RdrlWRRLk=x WrinWRS WrlsRDS Clrs RdlsClrls SUBSetday SettimeSetdate RdtimeSET1ALRM1 Mode 1 Every Minute Alarm #1 CommandsSET1ALRM2 Mode 2 Every Hour RddateSET1ALRM4 Mode 4 Once a Month SET1ALRM3 Mode 3 Once a DaySET1ALRM5 Mode 5 Once a Week ALRM1=SUB10SET2ALRM1 Mode 1 Every Minute Alarm #2 CommandsSET2ALRM2 Mode 2 Every Hour ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM4 Mode 4 Once a Month SET2ALRM3 Mode 3 Once a DaySET2ALRM5 Mode 5 Once a Week ALRM2=SUB10Alrmoff AlrmonRdalrm ALRMn=SUBkRDM WrlmRdlm ClrmOutpdpm ModersiSendrs OutvcmSendbs SendpsMdoff Mdon58. MD1 59. MD0Rdmd MdtypeMD0=SUB10 MD1=SUB11 RSISIDnCi Summary of CommandsRSN Rddate Display date from clockInternal Command Format Sending Commands to Internal BUSPlasma Control with Internal BUS Pioneer Plasma Commands Troubleshooting GuideThere is no Communication Relays do not WorkAltinex Policies Limited WARRANTY/RETURN PoliciesInput Ports do not Respond Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.