Altinex PE1005 manual Rdrl, WRRLx1x2x3x4, WRRLk=x, Wrin, Rdin

Page 13

SPECIAL APPLICATION

7.[RDRL]

This command is used to read the status of one or all of the internal relays. A ‘1’ indicates the relay is on (closed). A ‘0’ indicates the relay is off (open).

Command Format: [RDRLnCi]

n = Relay No. (1, 2, 3, 4 or * for all)

Ci = Unit ID (i = # from 1 to 99)

Example 1:

The PE1005 has relay number one on (closed) and two through four are off. Send the command [RDRL*] to check the status of all relays. The feedback will be as follows:

1000

Example 2:

Check the status of relay number one only by sending the command [RDRL1]. The feedback will be as follows:

1

8.[WRRLx1x2x3x4]

This command is used to the turn the internal relays on or off. A ‘1’ will close the relay, a ‘0’ will open a relay and an ‘X’ will leave the status of the relay unchanged.

Command Format: [WRRLx1x2x3x4Ci] x1 = Relay #1

x2 = Relay #2

x3 = Relay #3

x4 = Relay #4

x = 0 for open, or off x = 1 for closed or on x = X for no change

Ci = Unit ID (i = # from 1 to 99)

Example:

Set relay 1 on, relay 4 off, and leave relays 2 and 3 unchanged. In order to do this, send the command [WRRL1XX0].

9.[WRRLk=x]

This command is used to set one or all internal relays on or off. A ‘1’ will close the relay and a ‘0’ will open a relay.

Command Format: [WRRLk=xCi]

k = Relay No. (1, 2, 3, 4 or * for all)

x = Relay Setting (0 = open, 1 = closed)

Ci = Unit ID (i = # from 1 to 99)

Example:

Set only relay 1 on by sending the command [WRRL1=1].

10.[WRIN]

This command is used to assign a subroutine number to be executed when one of the input ports makes a high-to-low transition. In order to create a high-to-low transition, connect the input port to ground using a switch or other contact closure device.

Command Format: [WRINn=SUBkCi]

n = Input No. (1, 2, 3 or 4)

k = Subroutine (k = # from 1 to 99)

Ci = Unit ID (i = # from 1 to 99)

Example:

Assign subroutine 10 to be performed when port one makes a high-to-low transition. In order to do this, send the command [WRIN1=SUB10]. Now when input port one is shorted to ground, subroutine 10 will be executed.

11.[RDIN]

This command is used to read the subroutine settings for the input ports.

Command Format: [RDINnCi]

n = Input No. (1, 2, 3, 4 or * for all)

Ci = Unit ID (i = # from 1 to 99)

400-0384-003

12

Image 13
Contents PE1005 Table of Contents Precautions / Safety Warnings About Your PE1005 Technical SpecificationsDiagram 1 Typical Setup Application DiagramsDescription of PE1005 Pioneer Control Card Diagram 2 Internal ViewBattery Diagram 3 Card DetailsLED1 SW1Diagram 5 Motion Detector Details Diagram 4 25-PIN HD DetailsExternal Port Setup Installing Your PE1005USB Setup TCP/IP SetupIP Address Configure the DeviceFreset Description of CommandsOperation StatusTest VERWait RDIWRRLx1x2x3x4 RdrlWRRLk=x WrinWrls WRSRDS Clrs RdlsClrls SUBSetday SettimeSetdate RdtimeSET1ALRM1 Mode 1 Every Minute Alarm #1 CommandsSET1ALRM2 Mode 2 Every Hour RddateSET1ALRM4 Mode 4 Once a Month SET1ALRM3 Mode 3 Once a DaySET1ALRM5 Mode 5 Once a Week ALRM1=SUB10SET2ALRM1 Mode 1 Every Minute Alarm #2 CommandsSET2ALRM2 Mode 2 Every Hour ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM4 Mode 4 Once a Month SET2ALRM3 Mode 3 Once a DaySET2ALRM5 Mode 5 Once a Week ALRM2=SUB10Alrmoff AlrmonRdalrm ALRMn=SUBkRDM WrlmRdlm ClrmOutpdpm ModersiSendrs OutvcmSendbs SendpsMdoff Mdon58. MD1 59. MD0Rdmd MdtypeMD0=SUB10 MD1=SUB11 RSISIDnCi Summary of CommandsRSN Rddate Display date from clockSending Commands to Internal BUS Internal Command FormatPlasma Control with Internal BUS Pioneer Plasma Commands Troubleshooting GuideThere is no Communication Relays do not WorkAltinex Policies Limited WARRANTY/RETURN PoliciesInput Ports do not Respond Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.