Altinex PE1005 manual Mdtype, Rdmd, MD0=SUB10 MD1=SUB11, Rsi, SIDn

Page 26

SPECIAL APPLICATION

Command Format: [SETMD=xCi]

x = Time Delay (x = # from 01 to 99)

01 = 0.1 minutes (6 sec)

02 = 0.2 minutes (12 sec)

99 = 9.9 minutes

Ci = Unit ID (i = # from 1 to 99)

Example:

Set the time delay to a value of one minute by sending the command [SETTMD=10]. Use the [RDMD] command to read values and check settings.

62.[MDTYPE]

This command sets the motion detector’s time delay. The sensor will trigger until a target is found and then stop sensing and not check for a new target until after the specified delay time. The range is 01 to 99, where each increment is

0.1minutes and the minimum delay time is 6 seconds.

Command Format: [MDTYPE=xCi]

x = Sensor Type (x = 0 or 1)

0 = Ultrasound Motion Detector

1 = PIR Motion Detector Ci = Unit ID (i = # from 1 to 99)

Example:

Set the time delay to a value of one minute by sending the command [SETTMD=10]. Use the [RDMD] command to read values and check settings.

63.[RDMD]

Use this command to display the motion detector’s settings and check its status. The status includes the settings, assigned subroutines, current detected reading, and whether or not the motion detector is active.

Command Format: [RDMDCi]

Ci = Unit ID (i = # from 1 to 99)

Example:

The motion detector’s trigger level is set to 1.0V. Subroutine 10 is assigned for objects moving away from the detector, and subroutine 11 is assigned for objects moving toward the detector. Send the command [RDMD] and receive feedback similar to the following:

Motion Detector ON

MD Current value:04

MD Threshold value:10

MD0=SUB10

MD1=SUB11

ID COMMANDS – RSI, SIDn, SIDnCi, RSN

64.[RSI]

This command resets the card IDs in the system. After sending this command, each card ID will be ‘0’.

Command Format: [RSI]

Example:

Send the command [RSI] to the system with ID 2. The card can no longer be recognized as ID 2, it will be ID 0.

REMEMBER: A command sent without the unit ID will be executed by all the PE1005s connected to the RS-232 port.

65.[SIDn]

This command sets the ID number of all cards connected to the RS-232 bus to the same value. The default unit ID is zero.

Command Format: [SIDn]

n= New ID (n = # from 1 to 99) Example:

Send the command [SID1] to the system. The card ID is now one, and “C1” must be included at the end of each command line, as in “[VERC1]”, for only the unit with ID1 to respond.

400-0384-003

25

Image 26
Contents PE1005 Table of Contents Precautions / Safety Warnings Technical Specifications About Your PE1005Description of PE1005 Application DiagramsDiagram 1 Typical Setup Diagram 2 Internal View Pioneer Control CardLED1 Diagram 3 Card DetailsBattery SW1Diagram 4 25-PIN HD Details Diagram 5 Motion Detector DetailsUSB Setup Installing Your PE1005External Port Setup TCP/IP SetupConfigure the Device IP AddressOperation Description of CommandsFreset StatusWait VERTest RDIWRRLk=x RdrlWRRLx1x2x3x4 WrinRDS WRSWrls Clrls RdlsClrs SUBSetdate SettimeSetday RdtimeSET1ALRM2 Mode 2 Every Hour Alarm #1 CommandsSET1ALRM1 Mode 1 Every Minute RddateSET1ALRM5 Mode 5 Once a Week SET1ALRM3 Mode 3 Once a DaySET1ALRM4 Mode 4 Once a Month ALRM1=SUB10SET2ALRM2 Mode 2 Every Hour Alarm #2 CommandsSET2ALRM1 Mode 1 Every Minute ALRM2=SUB10 SET2ALRM1 ALRMON2SET2ALRM5 Mode 5 Once a Week SET2ALRM3 Mode 3 Once a DaySET2ALRM4 Mode 4 Once a Month ALRM2=SUB10Rdalrm AlrmonAlrmoff ALRMn=SUBkRdlm WrlmRDM ClrmModersi OutpdpmSendbs OutvcmSendrs Sendps58. MD1 MdonMdoff 59. MD0MD0=SUB10 MD1=SUB11 MdtypeRdmd RSIRSN Summary of CommandsSIDnCi Rddate Display date from clockPlasma Control with Internal BUS Internal Command FormatSending Commands to Internal BUS There is no Communication Troubleshooting GuidePioneer Plasma Commands Relays do not WorkInput Ports do not Respond Limited WARRANTY/RETURN PoliciesAltinex Policies Contact Information ALTINEX, Inc

PE1005 specifications

The Altinex PE1005 is an innovative solution in the world of presentation technology, designed primarily for enhancing audio-video management in various environments, including educational institutions, corporate offices, and conference spaces. As a versatile power distribution unit, the PE1005 provides a reliable way to connect multiple devices while ensuring optimal functionality and safety.

One of the standout features of the Altinex PE1005 is its robust power management capability. With several AC outlets available, it allows users to plug in essential equipment such as projectors, computers, and audiovisual devices. The smart configuration minimizes the risk of power disruptions and overloads, offering peace of mind during critical presentations.

In terms of design, the PE1005 is compact, making it easy to integrate into various setups without taking up valuable space. Its sleek and professional appearance is complementary to modern office aesthetics, ensuring that it not only functions effectively but also supports the overall visual appeal of the workspace.

The Altinex PE1005 is equipped with advanced surge protection technology, providing an additional layer of security for connected devices. This feature is crucial in protecting valuable equipment from power spikes or electrical surges, thereby extending the lifespan of essential gear and reducing maintenance costs.

Another vital characteristic of the PE1005 is its user-friendly interface. The layout of ports and controls is intuitive, allowing users to quickly connect and manage devices with minimal training. This ease of use is particularly beneficial in high-paced environments where time is of the essence.

Moreover, the Altinex PE1005 supports various connectivity options, including USB ports, which facilitate quick charging and data transfer for mobile devices. This versatility ensures greater functionality and servicing options for users who rely on multiple types of equipment during presentations.

The PE1005 also emphasizes safety and compliance with relevant standards, ensuring that it can be used confidently across different settings. Whether in classrooms, boardrooms, or conference centers, the Altinex PE1005 stands out as a reliable tool for ensuring seamless presentations and effective power management.

Overall, the Altinex PE1005 represents a fusion of functionality, safety, and ease of use, making it a vital asset for anyone looking to optimize their audiovisual experience. With its blend of advanced technology and practical features, it is an ideal solution for modern presentation needs.