Black Box RMU200 manual General Keyboard Conventions, Cursor Movement, Parameter Changing

Page 14

G-Converter Chassis

General Keyboard Conventions

Only a few keys are required to configure the chassis and are summarised as follows:

(Right arrow)

Moves the cursor to the next field to the right.

(Left arrow)

Moves the cursor to the next field to the left.

(Up arrow)

Moves the cursor to the next field upwards.

(Down arrow)

Moves the cursor to the next field downwards.

+

(Plus) or <SPACEBAR>

Toggles the parameter value up to the next available setting.

(Minus)

Toggles the parameter value down to the next available setting.

<ENTER> or <RETURN>

Accepts the current display page (otherwise the same as ↓ ).

<CTRL> and U

Updates all changes.

<ESC>

Abandons all changes since the last <CTRL> U.

<CTRL> and P

Refresh screen.

Cursor Movement

The cursor symbol “>” is moved around the screen to the required field using the arrow keys.

Parameter Changing

If it is possible to modify the field over which the cursor is placed, an appropriate message is shown at the bottom of the screen. No message will appear if the field is non-configurable.

Pressing the Space bar, the “+” key or the “-“ key will cycle through the choices available for a parameter.

Accepting all changes and Updating the Configuration

If “Control” and “U” are pressed at the same time after the configuration has been altered, the configuration is updated at the local and remote end as necessary and held in non-volatile Memory.

14 SALES: 0118 965 5100

Image 14 Contents
Converter Chassis Converter Chassis Converter Chassis Contents Converter Chassis Converter System’s Chassis Introduction OverviewManager Card Removal of Manager Card Power SuppliesManager Card LED Indication Card Cage System InstallationEnvironmental Considerations Channel CardsManagement Overview Supervisor Terminal Emulation Supervisor Port terminal managementSupervisor Terminal Requirements Typical Configuration Display General set-up Display LayoutCursor Movement Accepting all changes and Updating the ConfigurationGeneral Keyboard Conventions Parameter ChangingAbandoning Changes Changing the ConfigurationRestoring the Factory Default Configuration Base-T Port Telnet Management Supervisor Terminal Requirements Typical Configuration Display General Keyboard Conventions Telnet Screen Ethernet Screen IP Screen Alarms Screen Events Screen Snmp Management Configuration Sales 0118 965 Typical Configuration Display General Keyboard Conventions Abandoning Changes Fan Assembly DiagnosticsPower Supply Snmp TrapsInstallation of Equipment Appendix A- WarningsConverter Chassis Appendix B -Approval Requirements 703/G.704Appendix C EMC Requirements DCD