Black Box RMU200 Installation, Environmental Considerations, Card Cage System, Channel Cards

Page 10

G-Converter Chassis

Installation

Before installation, refer to the safety warnings, approvals requirements and emc requirements in the appendices.

Environmental Considerations

The equipment must be operated under the following atmospheric conditions:

Temperature:

0 to 40 degrees centigrade.

Humidity:

0% to 90% non-condensing.

Card Cage System

The Card Cage System should be housed in a cabinet that is considered by EN60950 to be a suitable electrical and fire enclosure. Refer to Appendix A for safety warnings. A fixing flange is fitted to the front of the Card Cage to mount the unit into the cabinet.

Manager Card

Note: THE MANAGER CARD MUST ONLY BE PLUGGED INTO SLOT 19.

The Manager Card is connected to the 9 Way-D Supervisor Port, and the RJ45 10Base-T port, located adjacent to the fan on the rear of the Card Cage. Connection between individual Channel Cards and the Manager Card is achieved via the back plane (See Figures 1 and 2).

There are no user configurable links on the Manager Card.

Power Supplies

The Power Supplies are installed in Slots 20 and 21. Slot 21 is located on the extreme right hand side of the Card Cage, when viewing it from the front, (See Figure 1). Mains power for Slots 20 and 21 is provided by a pair of IEC connectors, the upper connector is allocated for Slot 21, the lower connector for Slot 20.

When only one Power Supply is fitted it should be into Slot 21 with mains power being supplied via the upper IEC connector. A blanking panel should be installed to cover Slot 20.

Channel Cards

Channel Cards for the Card Cage may be selected to meet several requirements; the cards are fitted into slots 1 to 18. The cards can be ‘hot swapped’ by simply releasing the retaining screws on the top and bottom of the panel and with the aid of the injector/ejector handles carefully withdrawing the card. Simply reverse this process to install a card.

10 SALES: 0118 965 5100

Image 10
Contents Converter Chassis Converter Chassis Converter Chassis Contents Converter Chassis Converter System’s Chassis Introduction OverviewManager Card Manager Card LED Indication Power SuppliesRemoval of Manager Card Card Cage System InstallationEnvironmental Considerations Channel CardsManagement Overview Supervisor Terminal Requirements Supervisor Port terminal managementSupervisor Terminal Emulation Typical Configuration Display General set-up Display LayoutCursor Movement Accepting all changes and Updating the ConfigurationGeneral Keyboard Conventions Parameter ChangingRestoring the Factory Default Configuration Changing the ConfigurationAbandoning Changes Base-T Port Telnet Management Supervisor Terminal Requirements Typical Configuration Display General Keyboard Conventions Telnet Screen Ethernet Screen IP Screen Alarms Screen Events Screen Snmp Management Configuration Sales 0118 965 Typical Configuration Display General Keyboard Conventions Abandoning Changes Fan Assembly DiagnosticsPower Supply Snmp TrapsInstallation of Equipment Appendix A- WarningsConverter Chassis Appendix B -Approval Requirements 703/G.704Appendix C EMC Requirements DCD