G-Converter Chassis
10 Base-T Port (Telnet Management)
This method uses the 10
Before Telnet or SNMP management is used, it is essential that the notes relating to Supervisor Port Management be studied. (See
To enable SNMP or Telnet management, information must be added to the Manager Card via the Supervisor Port. The user must first set up various parameters namely IP address, Subnet Mask and Gateway.
The information required is:
System Name
A text field to identify the system. May be up to 32 characters.
Location
A text field to identify the location of the system. May be up to 32 characters.
IP Address
The IP address of the system. This must be set from the supervisor port to enable SNMP or Telnet access.
Subnet Mask
The Subnet mask of the local network. This must be set from the supervisor port before SNMP and Telnet access is required.
Gateway
The IP address of the default gateway from the local network.
To assist the process of adding this information, the relating to Supervisor port management is detailed below.