Carrier ZONEKIT4ZCAR instruction manual ÐTypical Wiring Diagrams Furnace with Air Conditioner

Page 24

COMFORT ZONE CENTER

STANDARD

SINGLE SPEED

AIR CONDITIONER

VARIABLE SPEED

FURNACE

COMFORT ZONE CENTER

STANDARD

SINGLE SPEED

AIR CONDITIONER

FURNACE

UNIT 24 VAC (R) COOL 1 (Y1) COOL 2 (Y2) HEAT 1 (W1) HEAT 2 (W2) FAN (G)

RV-COOL (O)

OR

RV-HEAT (O)

Red

Yellow

Blue

White

Brown

Green

Orange

Black

R

C

Y

C

Y

W

G

UNIT 24 VAC (R) COOL 1 (Y1) COOL 2 (Y2) HEAT 1 (W1) HEAT 2 (W2) FAN (G)

RV-COOL (O)

OR

RV-HEAT (O)

Red

Yellow

Blue

White

Brown

Green

Orange

Black

R

 

C

C

Y

Y

W

 

G

 

 

A93220

NOTE: Put set-up Switch No. 2 at the control board to the ON position (up) when using Two Stage Relay Kit KGATT0101VSP Accessory (Optional)

 

(KGATT0101VSP)

RELAY

Black

COIL

 

1

3

 

(P5)

 

CONNECTION AT

 

CONTROL BOARD

 

A93219

B

A

COMFORT ZONE CENTER

STANDARD

SINGLE-SPEED

AIR CONDITIONER

FURNACE

COMFORT ZONE CENTER

2-SPEED

AIR CONDITIONER

(38TD)

VARIABLE SPEED

FURNACE

UNIT 24 VAC (R) COOL 1 (Y1) COOL 2 (Y2) HEAT 1 (W1) HEAT 2 (W2) FAN (G)

RV-COOL (O)

OR

RV-HEAT (O)

Red

Yellow

Blue

White

Brown

Green

Orange

Black

R

 

C

C

Y/Y2

Y

W/W1

 

W2

 

G

 

UNIT 24 VAC (R) COOL 1 (Y1) COOL 2 (Y2) HEAT 1 (W1) HEAT 2 (W2) FAN (G)

RV-COOL (O)

OR

RV-HEAT (O)

Red

Yellow

Blue

White

Brown

Green

Orange

Black

R

Y

W

G

C

R

Y2

C

Y1

L

NOTE: Locking furnace into "low fire" may help prevent over conditioning in the heating mode. This will allow the furnace to stage between low and high fire. Before using this feature read furnace Installation Instructions for two-stage operation. Connect "W2" from the Comfort Zone Center to "W2" on the furnace control board.

See Furnace Installation Instructions For Details Involving Set-Up Switch Configuration and Two-Stage Furnace Operation.

C

A94035

 

D

A94036

 

Fig. 20ÐTypical Wiring Diagrams (Furnace with Air Conditioner)

24

Image 24
Contents ZONEKIT4ZCAR ÐWiring ÐCheck Equipment and JobsiteShielded Cable ÐWiring Requirements ÐInstall Comfort Zone CenterÐInstall Zone Dampers From MAX Comfort Zone Gage Length Wires Center toRound Metal Duct Work Rectangular Metal Duct WorkRound Flexible Duct Work Damper Mounting BracketÐInstall Barometric Bypass Damper ÐInstall Duct Temperature SensorÐRound Flexible Duct Work Rectangular Fibrous Glass Duct WorkÐInstall Dx Coil Sensor ÐInstall Four Zone ControllerÐInstall Remote Room Sensors or Smart Sensors Optional ÐSequence of OperationÐComfort Zone System Wiring Diagram Sequence of Events for a Normal Heating or Cooling Cycle Selection of a Reference Zone in the SystemPRE-POSITIONING Dampers and Starting the System FAN ÐZone Damper Positions Damper Position Versus Zone Demand Controlling the Zone DampersOperating the Heating and Cooling Equipment Control Strategy for Heating / Cooling StagesConfiguration Options for Equipment Operation ÐHeating System Option Vs. Type of Heater UsedÐAvailable Heating and Cooling Stages Vs. System Type Relay Pack to Hvac Equipment ConnectionsÐhvac Equipment Stages Vs. Zone Demand Stage Control During Equipment OperationHeating & Cooling Demand F Demand C Equipment Stages ÐProgrammable Options-Settings ÐConfiguring Four Zone ControllerProgrammable OPTIONS-SETTINGS ÐWiring Diagram Reference For ÐWiring DiagramsProgrammable OPTIONS-TOGGLES ÐStart-UpSystem Switches ÐProgramming SchedulesÐExample Weekly Schedule Controller DisplayZone Selector Dial Right AM Time Period PM Time Period WrongÐTemperature Sensor Calibrations ÐAccessoriesHome Access Module Smart Sensor and Smart Sensor Power PackOutside AIR Temperature Sensor ÐTroubleshootingToggle Setting OFF Default ÐToggle SummaryÐOperating Problems Symptom Possible CauseSF Error Code Description Solution HF Error Code Description Solution ÐTypical Wiring Diagrams Fan Coil with Air Conditioner Comfort Zone Center Speed AIR Conditioner ÐTypical Wiring Diagrams Furnace with Air Conditioner A94037 ÐTypical Wiring Diagrams Furnace with Air Conditioner ÐTypical Wiring Diagrams Fan Coil with Heat Pump A94044 ÐTypical Wiring Diagram Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump Comfort Zone Configuration Table Toggle Description Factory Record Default JOB SettingSetting Rotary

ZONEKIT4ZCAR specifications

The Carrier ZONEKIT4ZCAR is an innovative zoning system designed to enhance the comfort and efficiency of heating and cooling in residential and commercial spaces. Its functionality allows users to customize temperature settings in different areas of a building, which is especially valuable in larger homes or multi-room facilities.

One of the standout features of the ZONEKIT4ZCAR is its integration with Carrier’s advanced HVAC technology. This zoning system utilizes dampers that control airflow, directing heated or cooled air to specific areas as needed. This ensures that every room is maintained at the desired temperature without wasting energy on unused spaces. The system can effectively manage up to four different zones simultaneously.

The ZONEKIT4ZCAR is equipped with smart technology compatibility, allowing seamless integration with smart home systems. Users can control their zoning settings through mobile applications, voice commands, or smart thermostats. This feature enhances user convenience, providing access to temperature adjustments from anywhere in the home. Additionally, the system can be programmed to follow user schedules, optimizing energy usage and potentially lowering energy bills.

Another key characteristic of the Carrier ZONEKIT4ZCAR is its reliability and durability. Carrier is a well-respected brand in the HVAC industry, associated with high-quality products that are built to last. The ZONEKIT4ZCAR reflects this commitment, featuring robust construction and materials that ensure longevity and consistent performance.

The installation process of the ZONEKIT4ZCAR is designed to be straightforward, making it an appealing choice for both professionals and DIY enthusiasts. It is compatible with various Carrier heating and cooling systems, allowing for easy upgrades or replacements in existing setups.

In terms of energy efficiency, the ZONEKIT4ZCAR caters to environmentally conscious users. By allowing precise control over the climate in specific areas, the system reduces overall energy consumption, thereby lowering carbon footprints.

Finally, the ZONEKIT4ZCAR provides exceptional comfort and control, making it a smart investment for anyone looking to improve their indoor climate experience. With its combination of cutting-edge technology, user-friendly features, and energy efficiency, the Carrier ZONEKIT4ZCAR stands out in the HVAC market as a reliable choice for modern zoning solutions.