Carrier ZONEKIT4ZCAR ÐHeating System Option Vs. Type of Heater Used, Starting the Hvac Equipment

Page 10

Table 3ÐHeating System Option Vs. Type of Heater Used

HEATER TYPE USED

HEAT PUMP

TWO STAGE

DUAL FUEL

FAN ON

FOR COOLING ONLY

SYSTEM TOGGLE:

HEAT PUMP

SYSTEM SWITCH:

IN SYSTEM

TOGGLE:

T-6

TOGGLE: T-26

S-7

 

T-9

 

 

 

 

Single-Stage Heat Pump

On

Off

0oF (off)

Off

Two-Stage Heat Pump

On

On

0oF (off)

Off

Heat Pump/Furnace Dual

On

Off

10 to 60oF

Off

Fuel

 

 

 

 

Two-Stage Heat Pump,

On

On

0°F

Off

Furnace Dual Fuel*

 

 

 

 

 

 

 

 

 

Furnace Heat Only

Off

Off

0oF (off)

On or Off

Strip Heater Only

Off

Off

0oF (off)

Off

*Refer to 2-speed heat pump Installation and Start-Up Instructions for details regarding 2-speed heat pump operation. It is recommended that heat pump control board controls operation of this equipment and not Comfort Zone.

Table 4ÐAvailable Heating and Cooling Stages Vs. System Type

TYPE OF HVAC

COOLING STAGE 1

COOLING STAGE 2

HEAT STAGE 1

HEAT STAGE 2

HEAT STAGE 3

HEAT STAGE 4

EQUIPMENT USED

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Only, any Heater Type

Y1

Y2

W1

W2

--

--

 

 

 

 

 

 

 

Single-Stage Heat Pump

Y1

--

Y1

W1

W2

--

Two-Stage Heat Pump

Y1

Y2

Y1

Y2

W1

W2

 

 

 

 

 

 

 

For cooling applications, the second stage of an air conditioner is not necessarily more expensive to operate than first stage. But additional cooling can drive down the efficiency of a 2-speed air conditioner and longer use of first stage alone tends to deliver better humidity control in moist climates. Again, because of these advantages, Comfort Zone will attempt to minimize use of second stage cooling. This is not as great of a concern for a heating application, because the majority of small air conditioning systems sold today (5 tons and below) are single-stage cooling only.

heater. The electric strip heat is much more expensive to operate when comparing cost per unit of heat. Because auxiliary stages of heating tend to be more expensive to operate, Comfort Zone attempts to keep number of stages at a minimum.

CONFIGURATION OPTIONS FOR EQUIPMENT OPERATION

Comfort Zone has several configurable options which allow it to control different types of HVAC equipment and change the manner in which the equipment is controlled. This first group must be set given the type of HVAC equipment installed. These include:

1.Heat Pump Operation (Rotary Position T-6).

2.Two-Stage Heat Pump (Rotary Position T-26).

3.Dual Fuel trip temperature (Rotary Position S-7).

4.Auto Fan Off For Heat (Rotary Position T-9).

The second group modifies the way the HVAC equipment is controlled. These include:

1.Comfort Trend Staging (Rotary Position T-8).

2.System Mode Reselect (Rotary Position T-22).

3.High/Low Temperature Limits Enabled (Rotary Position T-10).

4.High Temperature Trip Limit (Rotary Position S-6).

5.Dx Sensor (Rotary Position T-27).

6.Smart Start (Heat Pump Strip Heat Economy Feature)

The first options which must be set are based upon the type heater or heaters used. These are shown in Table 3. The only option which appears to impact cooling operation is Two-Stage Heat Pump which implies the availability of 2 stages of cooling. In reality there are no changes to cooling control scheme.

Comfort Zone assumes that there are always 2 stages of cooling present. These are connected to the Comfort Zone Relay Pack on the Y1 and Y2 contacts.

RELAY PACK TO HVAC EQUIPMENT CONNECTIONS

Given system configuration, Comfort Zone can determine number of heating stages that it will actually control and which relay outputs will be used to control each stage of heat. Comfort Zone can control up to 4 stages of heat depending upon system configuration.

For cooling only applications with any type of heater, Comfort Zone will only control 2 stages of heat. If system uses a heat pump, then Comfort Zone will control 3 stages of heat. The additional stage is heat pump compressor contact. The auxiliary heat is still 2 stages. If system uses a 2 stage heat pump, then Comfort Zone will control 4 stages of heat, 2 stages for heat pump and 2 stages for auxiliary heat.

The Comfort Zone Relay Pack outputs are shown in Table 4. The Y1 and Y2 contacts are used for compressor contacts only. Comfort Zone operates heat pumps by energizing compressor contacts and controlling reversing valve through Reversing Valve (RV) relay output. The W1 and W2 contacts are always used for heat sources. These are heating only units such as furnaces, strip heaters, etc. The relay outputs for Comfort Zone 1.4 are shown in Table 4.

Under no circumstances may the W1 and Y1 contacts on the relay pack be jumpered together. This is a common practice for many heat pump installations but will cause improper operation of the Comfort Zone (1.4 or greater) system.

STARTING THE HVAC EQUIPMENT

Once Comfort Zone selects a mode, controller will use configu- ration options to modify control of HVAC equipment. The controller first selects number of stages of heating and cooling that may be applied to building load. The "available" stages are determined by Reference Zone temperature demand and are shown in Table 5.

Using Table 5, if Reference Zone has a 2.3°F demand, then Comfort Zone may use 2 stages of cooling or 2 stages of heating. The HVAC equipment may not have 3 stages of heat or even 2 stages of cooling. The table is only used to determine what equipment Comfort Zone is allowed to turn on at any given time during a heating or cooling cycle. Actual operation of stages depends on other variables as well.

Normally Comfort Zone will start equipment operation when it has a demand of 1.5°F or greater. In some cases, Comfort Zone will be facing a demand greater than 1.5°F when a mode is starting. This can occur when user changes setpoints in a zone or if a schedule

10change has reset the Comfort Setpoints.

Image 10
Contents ZONEKIT4ZCAR ÐCheck Equipment and Jobsite ÐWiringShielded Cable ÐInstall Zone Dampers ÐWiring RequirementsÐInstall Comfort Zone Center From MAX Comfort Zone Gage Length Wires Center toRound Flexible Duct Work Round Metal Duct WorkRectangular Metal Duct Work Damper Mounting BracketÐRound Flexible Duct Work ÐInstall Barometric Bypass DamperÐInstall Duct Temperature Sensor Rectangular Fibrous Glass Duct WorkÐInstall Remote Room Sensors or Smart Sensors Optional ÐInstall Dx Coil SensorÐInstall Four Zone Controller ÐSequence of OperationÐComfort Zone System Wiring Diagram Selection of a Reference Zone in the System Sequence of Events for a Normal Heating or Cooling CyclePRE-POSITIONING Dampers and Starting the System FAN Operating the Heating and Cooling Equipment ÐZone Damper Positions Damper Position Versus Zone DemandControlling the Zone Dampers Control Strategy for Heating / Cooling StagesÐAvailable Heating and Cooling Stages Vs. System Type Configuration Options for Equipment OperationÐHeating System Option Vs. Type of Heater Used Relay Pack to Hvac Equipment ConnectionsStage Control During Equipment Operation Ðhvac Equipment Stages Vs. Zone DemandHeating & Cooling Demand F Demand C Equipment Stages ÐConfiguring Four Zone Controller ÐProgrammable Options-SettingsProgrammable OPTIONS-SETTINGS Programmable OPTIONS-TOGGLES ÐWiring Diagram Reference ForÐWiring Diagrams ÐStart-UpSystem Switches ÐProgramming SchedulesZone Selector Dial ÐExample Weekly ScheduleController Display Right AM Time Period PM Time Period WrongHome Access Module ÐTemperature Sensor CalibrationsÐAccessories Smart Sensor and Smart Sensor Power PackOutside AIR Temperature Sensor ÐTroubleshootingToggle Setting OFF Default ÐToggle SummaryÐOperating Problems Symptom Possible CauseSF Error Code Description Solution HF Error Code Description Solution ÐTypical Wiring Diagrams Fan Coil with Air Conditioner Comfort Zone Center Speed AIR Conditioner ÐTypical Wiring Diagrams Furnace with Air Conditioner A94037 ÐTypical Wiring Diagrams Furnace with Air Conditioner ÐTypical Wiring Diagrams Fan Coil with Heat Pump A94044 ÐTypical Wiring Diagram Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump Setting Comfort Zone Configuration TableToggle Description Factory Record Default JOB Setting Rotary

ZONEKIT4ZCAR specifications

The Carrier ZONEKIT4ZCAR is an innovative zoning system designed to enhance the comfort and efficiency of heating and cooling in residential and commercial spaces. Its functionality allows users to customize temperature settings in different areas of a building, which is especially valuable in larger homes or multi-room facilities.

One of the standout features of the ZONEKIT4ZCAR is its integration with Carrier’s advanced HVAC technology. This zoning system utilizes dampers that control airflow, directing heated or cooled air to specific areas as needed. This ensures that every room is maintained at the desired temperature without wasting energy on unused spaces. The system can effectively manage up to four different zones simultaneously.

The ZONEKIT4ZCAR is equipped with smart technology compatibility, allowing seamless integration with smart home systems. Users can control their zoning settings through mobile applications, voice commands, or smart thermostats. This feature enhances user convenience, providing access to temperature adjustments from anywhere in the home. Additionally, the system can be programmed to follow user schedules, optimizing energy usage and potentially lowering energy bills.

Another key characteristic of the Carrier ZONEKIT4ZCAR is its reliability and durability. Carrier is a well-respected brand in the HVAC industry, associated with high-quality products that are built to last. The ZONEKIT4ZCAR reflects this commitment, featuring robust construction and materials that ensure longevity and consistent performance.

The installation process of the ZONEKIT4ZCAR is designed to be straightforward, making it an appealing choice for both professionals and DIY enthusiasts. It is compatible with various Carrier heating and cooling systems, allowing for easy upgrades or replacements in existing setups.

In terms of energy efficiency, the ZONEKIT4ZCAR caters to environmentally conscious users. By allowing precise control over the climate in specific areas, the system reduces overall energy consumption, thereby lowering carbon footprints.

Finally, the ZONEKIT4ZCAR provides exceptional comfort and control, making it a smart investment for anyone looking to improve their indoor climate experience. With its combination of cutting-edge technology, user-friendly features, and energy efficiency, the Carrier ZONEKIT4ZCAR stands out in the HVAC market as a reliable choice for modern zoning solutions.