Carrier ZONEKIT4ZCAR instruction manual ÐTypical Wiring Diagrams Furnace with Air Conditioner

Page 26

COMFORT ZONE CENTER

2-SPEED

AIR CONDITIONER

(38TD)

FURNACE

UNIT 24 VAC (R) COOL 1 (Y1) COOL 2 (Y2) HEAT 1 (W1) HEAT 2 (W2) FAN (G)

RV-COOL (O)

OR

RV-HEAT (O)

Red

Yellow

Blue

White

Brown

Green

Orange

Black

R

R

C

C

W/W1

 

W2

 

G

Y1

Y/Y2

 

NOTE:

 

Locking furnace into

 

"low fire" may help

 

prevent over

 

conditioning in the

 

heating mode. This will

 

allow the furnace to

 

stage between low and

H

high fire. Before using

this feature read

 

furnace Installation

 

Instructions for two-

 

stage operation.

 

Connect "W2" from the

 

Comfort Zone Center

 

to "W2" on the furnace

 

control board.

 

L

Y2

See Furnace Installation

Instructions For Details

Involving Set-Up Switch

Configuration and Two-

Stage Furnace Operation.

Latent Capacity Control (LCC)

R1 = Relay DPST, Pilot Duty,

24-v coil (HN61KK324) or Equivalent. H = Humidistat, opens on humidity

rise (HL38MG026)

I

A93219

 

Fig. 20ÐTypical Wiring Diagrams (Furnace with Air Conditioner) Continued

26

Image 26
Contents ZONEKIT4ZCAR Shielded Cable ÐWiringÐCheck Equipment and Jobsite ÐInstall Zone Dampers ÐWiring RequirementsÐInstall Comfort Zone Center From MAX Comfort Zone Gage Length Wires Center toRound Flexible Duct Work Round Metal Duct WorkRectangular Metal Duct Work Damper Mounting BracketÐRound Flexible Duct Work ÐInstall Barometric Bypass DamperÐInstall Duct Temperature Sensor Rectangular Fibrous Glass Duct WorkÐInstall Remote Room Sensors or Smart Sensors Optional ÐInstall Dx Coil SensorÐInstall Four Zone Controller ÐSequence of OperationÐComfort Zone System Wiring Diagram PRE-POSITIONING Dampers and Starting the System FAN Sequence of Events for a Normal Heating or Cooling CycleSelection of a Reference Zone in the System Operating the Heating and Cooling Equipment ÐZone Damper Positions Damper Position Versus Zone DemandControlling the Zone Dampers Control Strategy for Heating / Cooling StagesÐAvailable Heating and Cooling Stages Vs. System Type Configuration Options for Equipment OperationÐHeating System Option Vs. Type of Heater Used Relay Pack to Hvac Equipment ConnectionsHeating & Cooling Demand F Demand C Equipment Stages Ðhvac Equipment Stages Vs. Zone DemandStage Control During Equipment Operation Programmable OPTIONS-SETTINGS ÐProgrammable Options-SettingsÐConfiguring Four Zone Controller Programmable OPTIONS-TOGGLES ÐWiring Diagram Reference ForÐWiring Diagrams ÐStart-UpSystem Switches ÐProgramming SchedulesZone Selector Dial ÐExample Weekly ScheduleController Display Right AM Time Period PM Time Period WrongHome Access Module ÐTemperature Sensor CalibrationsÐAccessories Smart Sensor and Smart Sensor Power PackOutside AIR Temperature Sensor ÐTroubleshootingToggle Setting OFF Default ÐToggle SummaryÐOperating Problems Symptom Possible CauseSF Error Code Description Solution HF Error Code Description Solution ÐTypical Wiring Diagrams Fan Coil with Air Conditioner Comfort Zone Center Speed AIR Conditioner ÐTypical Wiring Diagrams Furnace with Air Conditioner A94037 ÐTypical Wiring Diagrams Furnace with Air Conditioner ÐTypical Wiring Diagrams Fan Coil with Heat Pump A94044 ÐTypical Wiring Diagram Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump ÐTypical Wiring Diagrams Furnace with Heat Pump Setting Comfort Zone Configuration TableToggle Description Factory Record Default JOB Setting Rotary

ZONEKIT4ZCAR specifications

The Carrier ZONEKIT4ZCAR is an innovative zoning system designed to enhance the comfort and efficiency of heating and cooling in residential and commercial spaces. Its functionality allows users to customize temperature settings in different areas of a building, which is especially valuable in larger homes or multi-room facilities.

One of the standout features of the ZONEKIT4ZCAR is its integration with Carrier’s advanced HVAC technology. This zoning system utilizes dampers that control airflow, directing heated or cooled air to specific areas as needed. This ensures that every room is maintained at the desired temperature without wasting energy on unused spaces. The system can effectively manage up to four different zones simultaneously.

The ZONEKIT4ZCAR is equipped with smart technology compatibility, allowing seamless integration with smart home systems. Users can control their zoning settings through mobile applications, voice commands, or smart thermostats. This feature enhances user convenience, providing access to temperature adjustments from anywhere in the home. Additionally, the system can be programmed to follow user schedules, optimizing energy usage and potentially lowering energy bills.

Another key characteristic of the Carrier ZONEKIT4ZCAR is its reliability and durability. Carrier is a well-respected brand in the HVAC industry, associated with high-quality products that are built to last. The ZONEKIT4ZCAR reflects this commitment, featuring robust construction and materials that ensure longevity and consistent performance.

The installation process of the ZONEKIT4ZCAR is designed to be straightforward, making it an appealing choice for both professionals and DIY enthusiasts. It is compatible with various Carrier heating and cooling systems, allowing for easy upgrades or replacements in existing setups.

In terms of energy efficiency, the ZONEKIT4ZCAR caters to environmentally conscious users. By allowing precise control over the climate in specific areas, the system reduces overall energy consumption, thereby lowering carbon footprints.

Finally, the ZONEKIT4ZCAR provides exceptional comfort and control, making it a smart investment for anyone looking to improve their indoor climate experience. With its combination of cutting-edge technology, user-friendly features, and energy efficiency, the Carrier ZONEKIT4ZCAR stands out in the HVAC market as a reliable choice for modern zoning solutions.