38TDB
WeatherMaker™
Visit www.carrier.com
Installation and Start-Up Instructions
NOTE: Read the entire instruction manual before starting the installation.
This symbol → indicates a change since the last issue.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thor- oughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements.
Recognize safety information. This is the
Understand these signal words; DANGER, WARNING, CAU- TION, and NOTE. These words are used with the
Before installing, modifying, or servicing system, main elec- trical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. Electrical shock can cause personal injury or death.
Puron®
INSTALLATION RECOMMENDATIONS
NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.
1.Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer.
2.Ensure that vapor and liquid tube diameters are appropriate to capacity of unit.
A98516
Fig. 1—Model 38TDB
3.Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.
4.When passing refrigerant tubes through the wall, seal opening with RTV or other pliable
5.Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.
6.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing. (See Fig. 2.)
7.Ensure that tubing insulation is pliable and completely sur- rounds vapor tube.
8.When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 2.)
9.Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.
Outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected by 15 ft of
IMPORTANT: Maximum
IMPORTANT: Only install the
INSTALLATION
Step 1—Check Equipment and Job Site
UNPACK UNIT
Move to final location. Remove carton, taking care not to damage unit.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.