LEGEND
24 VOLT FACTORY WIRING
24 VOLT FIELD WIRING
FIELD SPLICE CONNECTION
RELAY SPDT, PILOT DUTY
OR EQUIVALENT
R1
H
AFS
HUMIDISTAT, OPENS ON HUMIDITY RISE (HL38MG026)
AIRFLOW SELECTOR
A01222
WIRING DIAGRAM NOTES:
1.WIRING MUST CONFORM TO NEC OR LOCAL CODES.
2.UNDERLINED LETTER ON THERMOSTAT TERMINAL INDICATES USAGE. FOR EXAMPLE: O/W2 MEANS O IS ENERGIZED IN COOLING MODE.
3.REFER TO INDOOR UNIT INSTALLATION INSTRUCTIONS FOR ANY ADDITIONAL FEATURES AND WIRING INFORMA- TION.
4.
5.PROGRAMMABLE MODEL
6.THERMIDISTAT DIP SWITCH NO. 1 SHOULD BE SET IN OFF POSITION FOR AIR CONDITIONER APPLICATIONS (FACTORY DEFAULT).
7.AS AN OPTION O/W2CAN CONTROL
8.THERMIDISTAT DIP SWITCH NO. 2 SHOULD BE SET IN THE ON POSITION FOR DUAL CAPACITY COMPRESSOR OPERATION.
9.TO ACTIVATE DEHUMIDIFY FUNCTION ON FK4 OR FV4, REMOVE J1 JUMPER AT FAN COIL CONTROL BOARD.
10.AS AN OPTION, LOCK FURNACE INTO
11.TO ACTIVATE DEHUMIDIFY FEATURE ON CURRENT STYLE,
12.THE DE JUMPERS MUST BE REMOVED TO ENABLE THE DEHUMIDIFICATION FEATURE ON FURNACE.
Table 2—Accessory Usage
| REQUIRED FOR | REQUIRED FOR | |
ACCESSORY | SEACOAST | ||
APPLICATIONS* | APPLICATIONS | ||
| (WITHIN 2 MILES) | ||
Coastal Filter | No | Yes | |
Support Feet | No | Recommended | |
Puron® | Yes† | Yes† | |
|
|
*For tubing line sets between 50 and 175 ft horizontal or 20 ft vertical differential, refer to Application Guideline and Service
† Required for all applications.
9