Carrier 38TDB instruction manual Accessory Usage, A01222, † Required for all applications

Page 9

LEGEND

24 VOLT FACTORY WIRING

24 VOLT FIELD WIRING

FIELD SPLICE CONNECTION

RELAY SPDT, PILOT DUTY 24-V COIL (HN61KK324)

OR EQUIVALENT

R1

H

AFS

HUMIDISTAT, OPENS ON HUMIDITY RISE (HL38MG026)

AIRFLOW SELECTOR

A01222

WIRING DIAGRAM NOTES:

1.WIRING MUST CONFORM TO NEC OR LOCAL CODES.

2.UNDERLINED LETTER ON THERMOSTAT TERMINAL INDICATES USAGE. FOR EXAMPLE: O/W2 MEANS O IS ENERGIZED IN COOLING MODE.

3.REFER TO INDOOR UNIT INSTALLATION INSTRUCTIONS FOR ANY ADDITIONAL FEATURES AND WIRING INFORMA- TION.

4.NON-PROGRAMMABLE MODEL 2S01–B, WHEN USED IN AIR CONDITIONING INSTALLATION THE R19 JUMPER MUST BE CUT AND REMOVED.

5.PROGRAMMABLE MODEL 2S01–B MUST HAVE DIP SWITCH C ON WHEN USED IN AIR CONDITIONER APPLICATIONS.

6.THERMIDISTAT DIP SWITCH NO. 1 SHOULD BE SET IN OFF POSITION FOR AIR CONDITIONER APPLICATIONS (FACTORY DEFAULT).

7.AS AN OPTION O/W2CAN CONTROL SECOND-STAGE HEAT.

8.THERMIDISTAT DIP SWITCH NO. 2 SHOULD BE SET IN THE ON POSITION FOR DUAL CAPACITY COMPRESSOR OPERATION.

9.TO ACTIVATE DEHUMIDIFY FUNCTION ON FK4 OR FV4, REMOVE J1 JUMPER AT FAN COIL CONTROL BOARD.

10.AS AN OPTION, LOCK FURNACE INTO LOW-FIRE OPERATION AND LET O/W2 CONTROL HIGH FIRE OPERATION. REFER TO FURNACE INSTALLATION INSTRUCTIONS FOR PROPER SETUP.

11.TO ACTIVATE DEHUMIDIFY FEATURE ON CURRENT STYLE, VARIABLE-SPEED, 80 PERCENT NON-CONDENSING, FURNACE DISCONNECT GREEN (DEHUM) WIRE FROM G ON FURNACE CONTROL BOARD AND CONNECT TO DEHUMIDIFY TERMINAL DHUM ON THERMIDISTAT.

12.THE DE JUMPERS MUST BE REMOVED TO ENABLE THE DEHUMIDIFICATION FEATURE ON FURNACE.

Table 2—Accessory Usage

 

REQUIRED FOR

REQUIRED FOR

ACCESSORY

LONG-LINE

SEACOAST

APPLICATIONS*

APPLICATIONS

 

(50-175 FT.)

(WITHIN 2 MILES)

Coastal Filter

No

Yes

Support Feet

No

Recommended

Puron® Balance-Port Hard

Yes†

Yes†

Shut-off TXV

 

 

*For tubing line sets between 50 and 175 ft horizontal or 20 ft vertical differential, refer to Application Guideline and Service Manual—Air Conditio ners and Heat Pumps Using Puron® Refrigerant. Crankcase heater and start assist are standard on two-speed units.

† Required for all applications.

9

Image 9
Contents Unpack Unit Check Equipment and Job SiteA98516 Book Catalog No Form 38TDB-4SI Replaces 38TDB-3SI TabInstall on a Solid, Level Mounting Pad Dimensions→ -Install TXV Clearance Requirements→ FAN Coil LONG-LINE ApplicationsMake Piping Connections Outdoor Unit Connected to FACTORY-APPROVED Indoor Unit Install LIQUID-LINE Filter DrierRefrigerant Tubing Sweat ConnectionMake Electrical Connections Install Electrical AccessoriesA01495 See notes 1, 2, 3, 6, 8, 10,See notes 1, 2, 3, 4, A01496A01501 See notes 1, 2, 3,See note 1, 2, 3, 4, A01504 A01502Make Airflow Selections Airflow Selection for 58CVA/58MVP FurnacesAirflow Selection for FK4C, FV4A, or 40FK FAN Coils Accessory Usage A01222† Required for all applications Start-Up A01192A00430 Required Liquid-Line Temperature F Check ChargeSystem Functions and Sequence of Operation Control Function LED Code High Capacity Only SubcoolingTemperature Thermistors Two-Speed Compressor Winding Resistance at 70F ±Final Checks A01513 Wiring Diagram-024, 036A01439 Wiring Diagram-037Wiring Diagram-060