Pressure Transducer

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief

Procedure on page 9.

NOTE: See Fig. 26 for this procedure.

1. Remove the displacement pump. See page 21.

29

2.

Use a pull±twist motion to remove the transducer

 

 

 

(29) from the pump manifold (101).

 

101

3.

Clean paint residue from the hole in the manifold;

 

 

 

do not scratch the surface of the hole.

 

 

4.

Lightly apply oil to the o-ring of the new transducer.

 

 

5.

Install the transducer in the pump manifold, while

Fig. 26

02817A

 

guiding the o-ring and backup ring into place.

 

 

 

 

 

6.Align the holes in the transducer as shown by the arrows in Fig. 26.

7.Install the displacement pump. See page 21.

Suction Hose

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief

Procedure on page 9.

1.Remove the drain hose (33) from the clip. Remove the front cover (13).

2.Pull upward on the hose (32) while unscrewing it from the inlet tube (38). The hose coupling (A) threads will engage and the hose will separate from the tube.

3.Replace the o±ring (27) if it is worn or damaged.

4.Lubricate the o±ring (27) and the inlet tube (38) threads with light grease.

5.Align the suction hose coupling with the threads of the inlet tube (38). Tighten the hose onto the tube at least 4 turns to ensure that the threads have disen- gaged and can function as a swivel joint.

CAUTION

Misalignment or cross-threading will damage the parts and/or create shavings which can cause the o±ring (27) to leak.

1Lubricate

Note: Filter not shown

13

 

33

 

36

 

32

1

27

 

A

 

38

Fig. 27

06978

 

￿￿￿￿￿￿ ￿￿

Image 27
Contents Performance 308715Symbols Table of ContentsInjection Hazard Fire Skin Injection Explosion Hazard Equipment Misuse HazardModel 231580 shown Component Function and IdentificationFire and Explosion Hazard SetupOperation How to use the gun trigger safetyHow to use the pressure control How to use the pressure drain valveHow to use the RAC IV tip guard How to remove a tip clogProcedure on Pressure Relief Procedure Startup ProcedureStartup Engage the gun safety latch Shutdown and Care Shutdown and CareFlushing When to FlushHow to Flush Follow the Pressure Relief Procedure onBasic Problem Solving TroubleshootingIntermediate Problem Solving No output motor runs but pump does not stroke Spray Pattern Variations Setup Motor TestArmature Short Circuit Test HOT Surface Hazard General Repair InformationTool List Moving Parts HazardMotor Brushes Test the brushes Displacement Pump Repair Repairing the pumpRemoving the pump See Fig Motor Power Supply Cord On/Off SwitchMotor Start Board Drive Housing, Connecting Rod, Crankshaft REF a Pressure Control Suction Hose Pressure TransducerReplacement Drain ValveRepair French Spanish German Greek Korean English Technical DataDimensions Graco Phone NumberModel 231580, Series a Model 232654, Series a Sprayer Parts DrawingSprayer Parts List Model 231580, Series A, Model 232654, Series aDescription Qty 644a 12b Motor Brush and Spring Replacement Kit Graco Warranty Additional Warranty CoverageLimitation of Liability