Setup

Grounding

WARNING

Improper installation or alteration of the grounding plug will result in a risk of electric shock, fire or explosion that could cause serious injury or death.

1.This equipment requires a 120 Vac, 60 Hz, 15A circuit with a grounding receptacle. See Fig. 3.

Grounded

Outlets

Grounding Prong

Fig. 3

2.Do not alter the ground prong or use an adapter.

3.A 12 AWG gauge, 50 ft extension cord may be used with this equipment.

Operation

How to use the gun trigger safety

When engaged, the gun safety latch prevents the gun from accidental triggering. See Fig. 4.

1Open or drain, position

2Closed, or spray position

1

2

WARNING

INJECTION HAZARD

If the gun still sprays when the gun trigger safety is locked, repair the gun. See manual 308645, supplied.

Gun safety latch shown engaged

Gun safety latch shown disengaged

1

2

1

2

Fig. 5

04646

 

How to use the pressure control.

The pressure control controls the motor operation so the sprayer maintains constant fluid pressure at the pump outlet. Turn the pressure control knob fully counterclockwise to obtain the minimum setting. Turn the knob clockwise to increase pressure. See Fig. 6.

Fig. 4

05964

 

How to use the pressure drain valve.

Use the pressure drain valve to relieve fluid pressure from the pump and to help prime the pump. If the valve senses an over pressure condition, it opens automati- cally to relieve fluid pressure. If this happens, stop spraying immediately, shut off and unplug the sprayer. Determine the cause of the problem and correct it before operating the sprayer again. Refer also to the Troubleshooting , page 13. See Fig. 5.

02824A

Fig. 6

3￿87￿5 7

Image 7
Contents Performance 308715Symbols Table of ContentsInjection Hazard Fire Skin Injection Explosion Hazard Equipment Misuse HazardModel 231580 shown Component Function and IdentificationFire and Explosion Hazard SetupOperation How to use the gun trigger safetyHow to use the pressure control How to use the pressure drain valveHow to remove a tip clog How to use the RAC IV tip guardProcedure on Startup Procedure Pressure Relief ProcedureStartup Engage the gun safety latch Shutdown and Care Shutdown and CareFlushing When to FlushHow to Flush Follow the Pressure Relief Procedure onBasic Problem Solving TroubleshootingIntermediate Problem Solving No output motor runs but pump does not stroke Spray Pattern Variations Motor Test SetupArmature Short Circuit Test HOT Surface Hazard General Repair InformationTool List Moving Parts HazardMotor Brushes Test the brushes Repairing the pump Displacement Pump RepairRemoving the pump See Fig Motor On/Off Switch Power Supply CordMotor Start Board Drive Housing, Connecting Rod, Crankshaft REF a Pressure Control Suction Hose Pressure TransducerDrain Valve ReplacementRepair French Spanish German Greek Korean English Technical DataDimensions Graco Phone NumberModel 231580, Series a Model 232654, Series a Sprayer Parts DrawingModel 231580, Series A, Model 232654, Series a Sprayer Parts ListDescription Qty 644a 12b Motor Brush and Spring Replacement Kit Additional Warranty Coverage Graco WarrantyLimitation of Liability