Hitachi 231580 manual How to use the RAC IV tip guard, How to remove a tip clog, Procedure on

Page 8

Operation

How to use the RAC IV tip guard.

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief

Procedure on page 9.

The tip guard alerts you to the risk and helps prevent placing any part of the body close to the spray tip. The tip guard also adjusts the vertical or horizontal spray pattern. See Fig. 9. The tip guard holds a reversing spray tip. The tip is in the spraying position when the tip handle points forward. See Fig. 7.

Clean the front of the tip frequently during the day's operation. First, follow the Pressure Relief Procedure on page 9.

12

Tip handle shown in

1spraying position.

2Turn handle 180_, trigger gun to clear clog

04647

Fig. 7

How to remove a tip clog.

1.Release the gun trigger. Lock the safety latch. Rotate the RAC IV tip handle 180_. See Fig. 7.

2.Unlock the safety latch. Trigger the gun into a pail or onto the ground to remove the clog.

3.Lock the safety latch. Rotate the tip handle to the spraying position.

4.If the tip is still clogged, lock the safety latch, shut off and unplug the sprayer, and open the pressure drain valve to relieve pressure. Clean the spray tip as shown in manual 308644, supplied.

83￿87￿5

Image 8
Contents 308715 PerformanceTable of Contents SymbolsInjection Hazard Equipment Misuse Hazard Fire Skin Injection Explosion HazardComponent Function and Identification Model 231580 shownSetup Fire and Explosion HazardHow to use the gun trigger safety How to use the pressure controlHow to use the pressure drain valve OperationProcedure on How to use the RAC IV tip guardHow to remove a tip clog Startup Pressure Relief ProcedureStartup Procedure Engage the gun safety latch Shutdown and Care Shutdown and CareWhen to Flush How to FlushFollow the Pressure Relief Procedure on FlushingTroubleshooting Basic Problem SolvingIntermediate Problem Solving No output motor runs but pump does not stroke Spray Pattern Variations Armature Short Circuit Test SetupMotor Test General Repair Information Tool ListMoving Parts Hazard HOT Surface HazardMotor Brushes Test the brushes Removing the pump See Fig Displacement Pump RepairRepairing the pump Motor Motor Start Board Power Supply CordOn/Off Switch Drive Housing, Connecting Rod, Crankshaft REF a Pressure Control Pressure Transducer Suction HoseRepair ReplacementDrain Valve Technical Data DimensionsGraco Phone Number French Spanish German Greek Korean EnglishSprayer Parts Drawing Model 231580, Series a Model 232654, Series aDescription Qty Sprayer Parts ListModel 231580, Series A, Model 232654, Series a 644a 12b Motor Brush and Spring Replacement Kit Limitation of Liability Graco WarrantyAdditional Warranty Coverage