Setup
NOTE: A 55 gallon (200 liter) suction tube kit, Part No. 236951, is available.
WARNING
If you are supplying your own hoses and spray gun, be sure the hoses are electrically conductive, that the gun has a tip guard, and that each part is rated for at least 3000 psi (207 bar, 21 MPa) Maxi- mum Working Pressure. This is to reduce the risk of serious injury caused by static sparking, fluid injection or
CAUTION
To avoid damaging the pressure control, which may result in poor equipment performance and compo- nent damage, follow these precautions.
1.Always use nylon spray hose. Never use a wire braid hose; it is too rigid to act as a pulsation dampener.
2.Always use a minimum hose length of 50 foot (15.2 m) x 3/8 inch ID hose at each outlet.
3.Never install any shutoff device between the filter (51) and main hose (202). See Fig. 2.
4.Always use the main filter outlet (60) for a one gun operation. Never plug this outlet.
1.Connect hose and gun. (Refer to Fig. 2.)
a.Remove the plastic cap from the 3/8 npsm (m) filter outlet nipple (60). Screw the 50 foot (15.2 m) main fluid hose (202) onto the nipple. Read the CAUTION, above.
b.Connect the whip end hose (203) between the main fluid hose and the inlet adapter of the gun (204).
c.DO NOT use thread sealant, and DO NOT install the spray tip yet!
2.Two gun hookup. Remove the cap (56) from the secondary hose outlet. Connect the second outlet hoses to the sprayer as explained in Step 1, above.
3.Fill packing nut/wetcup. Fill the packing nut/wet- cup (416) 1/3 full with Graco Throat Seal Liquid (TSL), supplied. See Fig. 2.
4.Check the engine oil level. Refer to the Honda engine manual, supplied. This is a summary of the information: Remove one of the oil fill plugs (P); the oil should be almost overflowing. See Fig. 3. Add oil as necessary.
Recommended lubrication oil: Use a
51
60416
56
202 204 203 Model 231327 shown
Fig. 2 | 03469A |
|
6308398